Schmersal
101181687
AES 2366 UE: 24...230V AC/DC
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Electrical data - Relay outputs (auxiliary contacts)
- Switching capacity, maximum
- 24 VDC
- Switching capacity, maximum
- 2 A
Electrical data
- Frequency range
- 50 Hz | 60 Hz
- Thermal test current
- 6 A
- Rated operating voltage
- 24 ... 230 VAC | 24 ... 230 VDC
- Rated AC voltage for controls, 50 Hz, minimum
- 20.4 VAC
- Rated control voltage at AC 50 Hz, maximum
- 253 VAC
- Rated AC voltage for controls, 60 Hz, minimum
- 20.4 VAC
- Rated control voltage at AC 60 Hz, maximum
- 253 VAC
- Rated AC voltage for controls at DC minimum
- 20.4 VDC
- Rated control voltage at DC, maximum
- 253 VDC
- Electrical power consumption
- 5 W
- Contact resistance, maximum
- 0.1 Ω
- Note (Contact resistance)
- in new state
- Drop-out delay in case of power failure, typically
- 80 ms
- Drop-out delay in case of emergency, typically
- 20 ms
- Pull-in delay at automatic start, maximum, typically
- 100 ms
- Pull-in delay at RESET, typically
- 20 ms
- Material of the contacts, electrical
- Ag-Ni 10 and 0.2 µm gold-plated
Note
- Note (General)
- Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Mechanical data - Dimensions
- Width
- 45 mm
- Height
- 100 mm
- Depth
- 121 mm
Ambient conditions - Insulation values
- Rated impulse withstand voltage U
- 4 kV
- Overvoltage category
- III
- Degree of pollution
- 2
Electrical data - Digital Output
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.1 A
General data - Features
- Stop-Category
- 0
- Wire breakage detection
- Yes
- Cross-circuit detection
- Yes
- Feedback circuit
- Yes
- Automatic reset function
- Yes
- Start-up test
- Yes
- Reset after disconnection of supply voltage
- Yes
- Integral system diagnostics, status
- Yes
- Number of LEDs
- 1
- Number of normally closed (NC)
- 2
- Number of normally open (NO)
- 2
- Number of undelayed semi-conductor outputs with signaling function
- 2
- Number of safety contacts
- 3
- Number of signalling outputs
- 2
General data
- Standards
- BG-GS-ET-14 | BG-GS-ET-20 | EN IEC 62061 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 61508 | EN IEC 60204-1 | EN IEC 60947-1
- Climatic stress
- EN 60068-2-3 | BG-GS-ET-14
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 125 g
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 61508
- Performance Level, up to
- d
- Category
- 3
- PFH value
- 1.00 x 10⁻⁷ /h
- Notice
- for max. 50,000 switching cycles/year and max. 80% contact load
- Safety Integrity Level (SIL), suitable for applications in
- 2
- Mission time
- 20 Year(s)
Wiring example
- Note (Wiring diagram)
- The wiring diagram is shown with guard doors closed and in de-energised condition. | Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range | To secure a guard door up to PL d and Category 3 | The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. | Start push button: A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated. | Expansion of the enable delay time. The enable delay time can be increased from X7 s to X8 s by mounting a jumper connection between the terminals 0,1 and 1. | If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and X2.
Other data
- Note (applications)
- Safety sensor | Guard system
Ambient conditions
- Degree of protection of the enclosure
- IP40
- Degree of protection of the mounting space
- IP54
- Degree of protection of clips or terminals
- IP20
- Ambient temperature
- +0 ... +55 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +70 °C
- Resistance to vibrations
- 10...55 Hz, Amplitude 0.35 mm, ± 15 %
- Restistance to shock
- 30 g / 11 ms
Mechanical data - Connection technique
- Termination
- rigid or flexible | Screw terminals M20 x 1.5
- Terminal designations
- IEC/EN 60947-1
- Cable section, minimum
- 0.25 mm²
- Cable section, maximum
- 2.5 mm²
- Tightening torque of Clips
- 0.6 Nm
Electrical data - Safe relay outputs
- Voltage, Utilisation category AC-15
- 230 VAC
- Current, Utilisation category AC-15
- 3 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 2 A
- Switching capacity, minimum
- 10 VDC
- Switching capacity, minimum
- 10 mA
- Switching capacity, maximum
- 250 VAC
- Switching capacity, maximum
- 8 A
Mechanical data
- Mechanical life, minimum
- 20,000,000 Operations
- Mounting
- Snaps onto standard DIN rail to EN 60715
Specifications
- Width
- 45 mm
- Height
- 100 mm
- Depth
- 121 mm
Approvals - Standards
- Certificates
- BG | cULus
Electrical data - Electromagnetic compatibility (EMC)
- EMC rating
- EMC-Directive
Electrical data - Digital inputs
- Input signal, HIGH Signal "1"
- 10 … 30 VDC
- Input signal, LOW Signal "0"
- 0 … 2 VDC
- Conduction resistance, maximum
- 40 Ω
Integral system diagnosis (ISD)
- Note (ISD -Faults)
- The following faults are registered by the safety monitoring modules and indicated by ISD.
- Faults
- Failure of the safety relay to pull-in or drop-out | Failure of door contacts to open or close | Cross-wire or short-circuit monitoring of the switch connections | Interruption of the switch connections | Fault on the input circuits or the relay control circuits of the safety monitoring module