Schmersal

101182988

AZ 200CC-T-1P2P
101182988
101182988
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
A total of 2 Parts In-Stock from 2 Distributors

Electrical data - Safety digital inputs

Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Current consumption at 24 V
5 mA

Electrical data

Operating voltage
24 VDC -15 % / +10 %
No-load supply current I
100 mA
Rated operating voltage
24 VDC
Operating current
50 mA
Time to readiness, maximum
4,000 ms
Switching frequency, approx.
1 Hz

Mechanical data - Dimensions

Length of sensor
50 mm
Width of sensor
40 mm
Height of sensor
220 mm

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Electrical data - Digital Output

Design of control elements
p-type

General data - Features

Actuator monitored
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of safety contacts
2

General data

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Working principle
Non-contact
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
345 g
Reaction time, maximum
60 ms
Duration of risk, maximum
120 ms

Safety classification

Standards
EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
4.00 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Rated operating current (safety outputs)
250 mA
Design of control elements
p-type
Voltage drop U
4 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Spring pulley connection
Cable section, minimum
0.25 mm²
Cable section, maximum
1.5 mm²
Note (Cable section)
All indications including the conductor ferrules.
Wire cross-section, minimum
23 AWG
Wire cross-section, maximum
15 AWG
Wire cross-section
23 ... 15 AWG
Allowed type of cable
solid single-wire | solid multi-wire | flexible

Electrical data - Diagnostic outputs

Voltage drop U
4 V
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Switch distance, typical
6.5 mm
Assured switching distance "ON" S
4 mm
Assured switching distance "OFF" S
30 mm

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Hysteresis (Switching distance), maximum
1.5 mm
Repeat accuracy R
0.5 mm
Latching force
30 N
Actuating speed, maximum
0.2 m/s
Tightening torque of the fastening screws for the housing cover, minimum
0.7 Nm
Tightening torque of the fastening screws for the housing cover, maximum
1 Nm
Note
Torx T10

Accessory

Recommendation (actuator)
AZ/AZM 200-B1

Approvals - Standards

Certificates
TÜV | cULus

Status indication

Note (LED switching conditions display)
Operating condition: LED green | Error / functional defect: LED red | Supply voltage: LED green