Electrical data

Thermal test current
6 A
Rated control voltage
110 VAC
Rated control voltage
230 VDC
Required rated short-circuit current
1,000 A
Electrical power consumption, maximum
10 W
Switching element
NO contact, NC contact
Switching principle
Slow action
Switching frequency
1,000 /h
Material of the contacts, electrical
Silver

Note

Note (Emergency exit)
The emergency exit is used where an intervention in an already locked hazardous area is required | Emergency exit by pressing the red push button | Resetting by pulling on the latched button | Top-side (ordering suffix -TD) or rear-side (ordering suffix -TU) mounting possible
Note (Manual release)
For maintenance, installation, etc. | For manual release using M5 triangular key, available as accessory | Top-side (ordering suffix -ED) or rear-side (ordering suffix -EU) mounting possible

Mechanical data - Dimensions

Length of sensor
30 mm
Width of sensor
130 mm
Height of sensor
90 mm

Ambient conditions - Insulation values

Rated insulation voltage U
250 VAC
Rated impulse withstand voltage U
4 kV

Electrical data - Safety contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
2.5 A

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Safety classification - Safety outputs

B
2,000,000 Operations
B
1,000,000 Operations
Note (B
at 10% I | and ohmic load

Electrical data - Magnet control

Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms

General data - Features

Power to unlock
Yes
Emergency exit
Yes
Manual release
Yes
Number of actuating directions
3
Number of auxiliary contacts
2
Number of safety contacts
4

General data

Standards
EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-1
Coding level according to EN ISO 14119
Low
Working principle
electromechanical
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
2.5 A

Safety classification

Standards
EN ISO 13849-1
Performance Level, up to
c
Safety Integrity Level (SIL), suitable for applications in
1
Mission time
20 Year(s)

Other data

Note (applications)
sliding safety guard | removable guard | hinged safety guard

Ambient conditions

Degree of protection
IP67
Ambient temperature
-30 ... +60 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Protection class
II
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Cage clamps
Cable entry
4 x M16 x 1,5
Cable section, minimum
0.25 mm²
Cable section, maximum
1.5 mm²
Note (Cable section)
All indications including the conductor ferrules.
Allowed type of cable
solid single-wire | solid multi-wire | flexible

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Actuating play in direction of actuation
5.5 mm
Holding force F
2,000 N
Holding force F
2,600 N
Latching force
30 N
Positive break travel
10 mm
Positive break force per NC contact, minimum
10 N
Positive break force, minimum
20 N
Actuating speed, maximum
2 m/s
Mounting
Screws
Type of the fixing screws
3x M6

Approvals - Standards

Certificates
cULus | CCC