Schmersal

101193631

EX-AZ 16-03ZVRK-3D
101193631
101193631
101193631
101193631
101193631
101193631
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Explosion protection

Explosion protection: regulations
EN IEC 60079-0 | EN IEC 60079-31
Explosion protection zones
22
Explosion protection category
3D
Explosion protection designation
II 3D Ex tc IIIC T90°C Dc X
Manufacturer declaration
Manufacturer declaration | Additional simple electrical apparatus (Zone 0 and 20)

Electrical data

Thermal test current
2.5 A
Utilisation category AC-15
230 VAC
Utilisation category AC-15
2.5 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
2.5 A
Switching element
Opener (NC)
Switching principle
Slow action
Material of the contacts, electrical
Silver

Note

Note (General)
Individual coding available on request

Mechanical data - Dimensions

Length of sensor
30 mm
Width of sensor
52 mm
Height of sensor
90 mm

Ambient conditions - Insulation values

Rated insulation voltage U
500 V
Rated impulse withstand voltage U
6 kV

Scope of delivery

Scope of delivery
Actuator must be ordered separately. | Slot sealing plugs | Including Ex-certified screwed cable gland and screw plug

Safety classification - Safety outputs

B
2,000,000 Operations
B
1,000,000 Operations
Note (B
at 10% I | and ohmic load

General data - Features

Increased latching force
Yes
Number of safety contacts
3

General data

Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
195 g

Safety classification

Standards
EN ISO 13849-1 | EN IEC 60947-5-1
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP67
Ambient temperature
-20 ... +70 °C

Mechanical data - Connection technique

Termination
Screw connection M16x1.5
Cable cross-section of the cable glands, minimum
6 mm
Cable cross-section of the cable glands, maximum
12 mm
Cable section, minimum
0.75 mm²
Cable section, maximum
2.5 mm²
Note (Cable section)
All indications including the conductor ferrules.

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Latching force
30 N
Positive break travel
8 mm
Positive break force, minimum
10 N
Actuating speed, maximum