Schmersal

101194954

BNS 36 AS-R
101194954
101194954
101194954
101194954
101194954
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data - AS-Interface specification

AS-i Specification
Safety-Slave
AS-i Version
V 2.1
AS-i Profile
S-0.B.F.E
AS-i, IO-Code
0x0
AS-i, ID-Code
0xB
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0 … DO 3
No Function
AS-i Parameter bits, P0 ... P3
No function
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF)
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Mechanical data - Dimensions

Length of sensor
13 mm
Height of sensor
25 mm

Pin assignment

PIN 1
Brown (AS interface +)
PIN 2
n.c.
PIN 3
Blue (AS interface −)
PIN 4
n.c.

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Coding
Yes
Integral system diagnostics, status
Yes

General data

Standards
EN IEC 62026-2 | EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Working principle
Magnetic drive
Installation conditions (mechanical)
quasi-flush
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
95 g
Reaction time, maximum
100 ms

Safety classification

Standards
EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
1.24 x 10⁻⁸ /h
Note (PFH-value)
up to max. 500,000 switching cycles/year
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - AS Interface

Rated operating voltage
18 ... 31.6 VDC (Protection against polarity reversal)
AS-i Current consumption, maximum
50 mA

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +60 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
Connecting cable, 2 pole
Length of cable
2 m
Wire cross-section
0.23 mm
Wire cross-section
23 AWG
Material of the Cable mantle
LSYY

Mechanical data - Switching distances according EN IEC 60947-5-3

Note (Switching distance Sn)
Axial misalignment, a horizontal and vertical misalignment of the safety sensor and the actuator are tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range.
Assured switching distance "ON" S
7 mm
Assured switching distance "OFF" S
17 mm

Mechanical data

Actuating element
Magnet
Door hinge
Right
Note (Repeat accuracy R)
Wiederholgenauigkeit R ≤ 0,1 x S
Direction of motion
Head-on to the active surface

Accessory

Recommendation (actuator)
BPS 36-2

Approvals - Standards

Certificates
TÜV | cULus | ASi-SaW

Status indication

Note (LED switching conditions display)
(1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0 | (2) LED yellow: Enabling status