Schmersal
101194954
BNS 36 AS-R
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Electrical data - AS-Interface specification
- AS-i Specification
- Safety-Slave
- AS-i Version
- V 2.1
- AS-i Profile
- S-0.B.F.E
- AS-i, IO-Code
- 0x0
- AS-i, ID-Code
- 0xB
- AS-i, ID-Code1
- 0xF
- AS-i, ID-Code2
- 0xE
- AS-i Input, Channel 1
- Data bits DI 0 / DI 1 = dynamic code transmission
- AS-i Input, Channel 2
- Data bits DI 2 / DI 3 = dynamic code transmission
- AS-i Outputs, DO 0 … DO 3
- No Function
- AS-i Parameter bits, P0 ... P3
- No function
- Note (AS-i Parameter bits)
- Set the parameter outputs to "1111" (0xF)
- AS-i Input module address
- 0
- Note (AS-i Input module address)
- Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Mechanical data - Dimensions
- Length of sensor
- 13 mm
- Height of sensor
- 25 mm
Pin assignment
- PIN 1
- Brown (AS interface +)
- PIN 2
- n.c.
- PIN 3
- Blue (AS interface −)
- PIN 4
- n.c.
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
General data - Features
- Coding
- Yes
- Integral system diagnostics, status
- Yes
General data
- Standards
- EN IEC 62026-2 | EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
- Working principle
- Magnetic drive
- Installation conditions (mechanical)
- quasi-flush
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 95 g
- Reaction time, maximum
- 100 ms
Safety classification
- Standards
- EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 1.24 x 10⁻⁸ /h
- Note (PFH-value)
- up to max. 500,000 switching cycles/year
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - AS Interface
- Rated operating voltage
- 18 ... 31.6 VDC (Protection against polarity reversal)
- AS-i Current consumption, maximum
- 50 mA
Ambient conditions
- Degree of protection
- IP67
- Ambient temperature
- -25 ... +60 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +70 °C
- Resistance to vibrations
- 10 … 55 Hz, amplitude 1 mm
- Restistance to shock
- 30 g / 11 ms
Mechanical data - Connection technique
- Termination
- Connecting cable, 2 pole
- Length of cable
- 2 m
- Wire cross-section
- 0.23 mm
- Wire cross-section
- 23 AWG
- Material of the Cable mantle
- LSYY
Mechanical data - Switching distances according EN IEC 60947-5-3
- Note (Switching distance Sn)
- Axial misalignment, a horizontal and vertical misalignment of the safety sensor and the actuator are tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range.
- Assured switching distance "ON" S
- 7 mm
- Assured switching distance "OFF" S
- 17 mm
Mechanical data
- Actuating element
- Magnet
- Door hinge
- Right
- Note (Repeat accuracy R)
- Wiederholgenauigkeit R ≤ 0,1 x S
- Direction of motion
- Head-on to the active surface
Accessory
- Recommendation (actuator)
- BPS 36-2
Approvals - Standards
- Certificates
- TÜV | cULus | ASi-SaW
Status indication
- Note (LED switching conditions display)
- (1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0 | (2) LED yellow: Enabling status
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories