Schmersal
101208004
CSP 11-34-D-M-ST
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Electrical data
- Operating voltage
- 24 VDC -15 % / +10 %
- No-load supply current I
- 100 mA
- Rated operating voltage
- 24 VDC
- Operating current
- 600 mA
- Required rated short-circuit current
- 100 A
- Utilisation category DC-12
- 24 VDC
- Utilisation category DC-12
- 0.05 A
- Utilisation category DC-13
- 24 VDC
- Utilisation category DC-13
- 0.05 A
- Note (Electrical data, Fuse rating)
- (Circuit breaker)
- Switching frequency, approx.
- 3 Hz
Note
- Note (General)
- Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary. | Coding of safety sensor and actuator: To activate the safety function (coding) of the CSP 34 for the first time, the associated actuator must be brought into the detection area of the switched on safety sensor. The automatic learn process of the actuator code is signalled on the safety sensor by the lighting up of the red LED and flashing of the yellow LED at the same time. After 10 seconds the cycling flashes indicate that the supply voltage of the safety sensor should be switched off for a few seconds so the code can be saved. | After the operating voltage is switched back on, the actuator must be detected once more in order to activate the taught actuator code. The assignment of safety sensor and actuator is permanently stored. The safety sensor can therefore not be activated by any other coding. | In order to protect the coding, the ordering details of the actuator are hidden by the mounting bracket.
Mechanical data - Dimensions
- Length of sensor
- 27 mm
- Width of sensor
- 35 mm
- Height of sensor
- 108.2 mm
Pin assignment
- PIN 1
- 1A1 Ue: (1)
- PIN 2
- X1 Safety input 1
- PIN 3
- A2 GND
- PIN 4
- Y1 Safety output 1
- PIN 5
- OUT Diagnostic output OUT
- PIN 6
- X2 Safety input 2
- PIN 7
- Y2 Safety output 2
- PIN 8
- IN without function
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VAC/DC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
Electrical data - Digital Output
- Design of control elements
- p-type
General data - Features
- Diagnostic output
- Yes
- Short circuit detection
- Yes
- Cross-circuit detection
- Yes
- Safety functions
- Yes
- Cascadable
- Yes
- Integral system diagnostics, status
- Yes
- Number of LEDs
- 3
- Number of semi-conductor outputs with signaling function
- 1
- Number of fail-safe digital outputs
- 2
- Number of series-wiring of sensors
- 31
General data
- Standards
- EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
- Working principle
- inductive
- Housing construction form
- Block
- Installation conditions (mechanical)
- not flush
- Sensor topology
- Sensor for series wiring
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Active area
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 111 g
- Reaction time, maximum
- 30 ms
- Duration of risk, maximum
- 60 ms
Safety classification
- Standards
- EN IEC 60947-5-3 | EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 3.60 x 10⁻⁹ /h
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - Safety digital outputs
- Rated operating current (safety outputs)
- 250 mA
- Output current, (fail-safe output), maximum
- 0.25 A
- Design of control elements
- p-type
- Voltage drop U
- 0.5 V
- Leakage current I
- 0.5 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.25 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
Ambient conditions
- Degree of protection
- IP65 | IP67
- Ambient temperature
- -25 ... +70 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Resistance to vibrations
- 10 … 55 Hz, amplitude 1 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- II
Mechanical data - Connection technique
- Termination
- Connector plug M12, 8-pole
- Note (length of the sensor chain)
- Cable length and cross-section change the voltage drop dependiing on the output current
Electrical data - Diagnostic outputs
- Operating current
- 50 mA
- Voltage drop U
- 5 V
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.05 A
Mechanical data - Switching distances according EN IEC 60947-5-3
- Switch distance, typical
- 11 mm
- Assured switching distance "ON" S
- 8 mm
- Assured switching distance "OFF" S
- 15 mm
Mechanical data
- Actuating panels
- lateral
- Active area
- lateral
- Hysteresis (Switching distance), maximum
- 1.5 mm
- Repeat accuracy R
- 0.5 mm
- Note (Repeat accuracy R)
- Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 30 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 8 mm.
Accessory
- Recommendation (actuator)
- CSP 34-S-1
- Recommended safety switchgear
- PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC
Approvals - Standards
- Certificates
- cULus
Electrical data - Electromagnetic compatibility (EMC)
- Interfering radiation
- IEC 61000-6-4
- EMC rating
- IEC 61000-6-2
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories