Electrical data

Operating voltage
24 VDC -15 % / +10 %
No-load supply current I
100 mA
Rated operating voltage
24 VDC
Operating current
600 mA
Required rated short-circuit current
100 A
Utilisation category DC-12
24 VDC
Utilisation category DC-12
0.05 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
0.05 A
Note (Electrical data, Fuse rating)
(Circuit breaker)
Switching frequency, approx.
3 Hz

Note

Note (General)
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary. | Coding of safety sensor and actuator: To activate the safety function (coding) of the CSP 34 for the first time, the associated actuator must be brought into the detection area of the switched on safety sensor. The automatic learn process of the actuator code is signalled on the safety sensor by the lighting up of the red LED and flashing of the yellow LED at the same time. After 10 seconds the cycling flashes indicate that the supply voltage of the safety sensor should be switched off for a few seconds so the code can be saved. | After the operating voltage is switched back on, the actuator must be detected once more in order to activate the taught actuator code. The assignment of safety sensor and actuator is permanently stored. The safety sensor can therefore not be activated by any other coding. | In order to protect the coding, the ordering details of the actuator are hidden by the mounting bracket.

Mechanical data - Dimensions

Length of sensor
27 mm
Width of sensor
35 mm
Height of sensor
108.2 mm

Pin assignment

PIN 1
1A1 Ue: (1)
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output OUT
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN without function

Ambient conditions - Insulation values

Rated insulation voltage U
32 VAC/DC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Electrical data - Digital Output

Design of control elements
p-type

General data - Features

Diagnostic output
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Safety functions
Yes
Cascadable
Yes
Integral system diagnostics, status
Yes
Number of LEDs
3
Number of semi-conductor outputs with signaling function
1
Number of fail-safe digital outputs
2
Number of series-wiring of sensors
31

General data

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Working principle
inductive
Housing construction form
Block
Installation conditions (mechanical)
not flush
Sensor topology
Sensor for series wiring
Enclosure material
Glass-fibre, reinforced thermoplastic
Active area
Glass-fibre, reinforced thermoplastic
Gross weight
111 g
Reaction time, maximum
30 ms
Duration of risk, maximum
60 ms

Safety classification

Standards
EN IEC 60947-5-3 | EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
3.60 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Rated operating current (safety outputs)
250 mA
Output current, (fail-safe output), maximum
0.25 A
Design of control elements
p-type
Voltage drop U
0.5 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
-25 ... +70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Connector plug M12, 8-pole
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current

Electrical data - Diagnostic outputs

Operating current
50 mA
Voltage drop U
5 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Switch distance, typical
11 mm
Assured switching distance "ON" S
8 mm
Assured switching distance "OFF" S
15 mm

Mechanical data

Actuating panels
lateral
Active area
lateral
Hysteresis (Switching distance), maximum
1.5 mm
Repeat accuracy R
0.5 mm
Note (Repeat accuracy R)
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 30 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 8 mm.

Accessory

Recommendation (actuator)
CSP 34-S-1
Recommended safety switchgear
PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC

Approvals - Standards

Certificates
cULus

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 61000-6-2