Schmersal

101210574

CSS 8-16-2P-E-L
101210574
101210574
101210574
101210574
101210574
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Electrical data

Operating voltage
24 VDC -15 % / +10 %
No-load supply current I
50 mA
Rated operating voltage
24 VDC
Operating current
1,100 mA | 500 mA
Switching frequency, approx.
3 Hz

Note

Note (General)
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.25 ms. Short-circuit recognition by the evaluation is not necessary.

Mechanical data - Dimensions

Length of sensor
39.5 mm
Width of sensor
55 mm
Height of sensor
93 mm

Pin assignment

PIN 1
A1 Ue Brown
PIN 2
Y2 safety output 2: White
PIN 3
A2 GND Blue
PIN 4
Y1 Safety output 1 Black

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Short circuit detection
Yes
Cross-circuit detection
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Number of series-wiring of sensors
16

General data

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Coding level according to EN ISO 14119
Low
Working principle
inductive
Housing construction form
Block
Installation conditions (mechanical)
not flush
Sensor topology
Individual sensor or end sensor in a series
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Active area
Glass-fibre, reinforced thermoplastic
Gross weight
315 g
Reaction time, maximum
30 ms
Duration of risk, maximum
30 ms

Safety classification

Standards
EN IEC 60947-5-3 | EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
2.50 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum
0.5 A
Design of control elements
p-type
Voltage drop U
0.5 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.5 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.5 A

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
-25 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Cable
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Length of cable
2 m
Terminal connector, Output
4-pole
Wire cross-section
0.5 mm
Wire cross-section
20 AWG

Electrical data - Diagnostic outputs

Design of control elements
p-type
Voltage drop U
4 V

Mechanical data - Switching distances according EN IEC 60947-5-3

Switch distance, typical
8 mm
Assured switching distance "ON" S
6 mm
Assured switching distance "OFF" S
11 mm

Mechanical data

Hysteresis (Switching distance), maximum
1 mm
Repeat accuracy R
0.5 mm

Accessory

Recommendation (actuator)
CST 16-1
Recommended safety switchgear
PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC

Approvals - Standards

Certificates
cULus

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 61000-6-2

Status indication

Note (LED switching conditions display)
Multi-coloured LED: Green, Red, Yellow