Electrical data - Safety digital inputs

Designation, Safety inputs
X1 and X2
Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Current consumption at 24 V
5 mA
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1 | C2 | C3

Electrical data

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
No-load supply current I
100 mA
Current consumption with magnet ON, average
350 mA
Current consumption with magnet ON, peak
550 mA / 10 ms
Rated operating voltage
24 VDC
Operating current
1,100 mA
Required rated short-circuit current
100 A
External wire and device fuse rating
2 A gG
Time to readiness, maximum
4,000 ms
Switching frequency, maximum
1 Hz

Note

Note (General)
As long as the actuating unit is applied to the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.

Mechanical data - Dimensions

Length of sensor
40 mm
Width of sensor
40 mm
Height of sensor
177.5 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN Solenoid control

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Electrical data - Magnet control

Designation, Magnet control
IN
Switching thresholds
-3 V … 5 V (Low) | 15 V … 30 V (High)
Current consumption at 24 V
10 mA
Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
40 ms
Classification ZVEI CB24I, Sink
C0
Classification ZVEI CB24I, Source
C1 | C2 | C3

General data - Features

Power to lock
Yes
Actuator monitored
Yes
Latching
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of safety contacts
2

General data

Standards
EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Universal coding
Coding level according to EN ISO 14119
Low
Working principle
inductive
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
623 g
Reaction time, maximum
150 ms
Duration of risk, maximum
150 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508

Electrical data - Safety digital outputs

Designation, Safety outputs
Y1 and Y2
Rated operating current (safety outputs)
250 mA
Design of control elements
short-circuit proof, p-type
Voltage drop U
1 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse interval, typical
1000 ms
Test pulse duration, maximum
1 ms
Classification ZVEI CB24I, Source
C1
Classification ZVEI CB24I, Sink
C1

Safety classification - Interlocking function

Performance Level, up to
e
Category
4
PFH value
3.54 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
-25 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing | non-icing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm / 5 g
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Connector M12, 8-pole
Length of sensor chain, maximum
200 m
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Electrical data - Diagnostic outputs

Designation, Diagnostic outputs
OUT
Design of control elements
short-circuit proof, p-type
Voltage drop U
2 V
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Assured switching distance "ON" S
0 mm
Assured switching distance "OFF" S
1 mm

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
Actuating speed ≤ 0.5 m/s | Operations for door weights ≤ 5 kg
Holding force, typically
750 N
Holding force, guaranteed
500 N
Latching force
60 N
Type of the fixing screws
2x M6
Tightening torque of the fixing screws
8 Nm

Accessory

Recommendation (actuator)
MZM 100-B1.1

Approvals - Standards

Certificates
TÜV | cULus | UKCA

Status indication

Note (LED switching conditions display)
Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green

CAD Models

Trace parts
Trace parts