Schmersal

101210928

AZM 170 B ST-AS P
101210928
101210928
101210928
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Electrical data - AS-Interface specification

AS-i Specification
Safety-Slave
AS-i Version
V 2.1
AS-i Profile
S-7.B.F.E
AS-i, IO-Code
0x7
AS-i, ID-Code
0xB
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0
Solenoid control
AS-i Outputs, DO 1
No Function
AS-i Outputs, DO 2
No Function
AS-i Outputs, DO 3
No Function
AS-i Parameter bits, P0
Safety guard and actuator detected
AS-i Parameter bits, P1
Solenoid interlock locked
AS-i Parameter bits, P2
No function
AS-i Parameter bits, P3
No function
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Note

Note (General)
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened.

Mechanical data - Dimensions

Width of sensor
90 mm
Height of sensor
75.5 mm

Pin assignment

PIN 1
AS-i +
PIN 2
Aux - (P)
PIN 3
AS-Interface -
PIN 4
Aux + (P)

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Power to unlock
Yes
Actuator monitored
Yes
Integral system diagnostics, status
Yes
Number of actuating directions
2

General data

Standards
EN IEC 62026-2 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 61508
Working principle
electromechanical
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
300 g
Reaction time, maximum
100 ms

Safety classification

Standards
EN IEC 61508
Performance Level, up to
c
Category
1
PFH value
1.16 x 10⁻⁶ /h
Note (PFH-value)
up to max. 100,000 switching cycles/year
Safety Integrity Level (SIL), suitable for applications in
1
Mission time
20 Year(s)
Please note:
Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende Beschädigung der 1-kanaligen Mechanik zulässig ist und ein ausreichender Manipulationsschutz gewährleistet ist.
Performance Level, up to
d
Category
3
PFH value
1.01 x 10⁻⁷ /h
Safety Integrity Level (SIL), suitable for applications in
2

Electrical data - AS Interface

Rated operating voltage
26.5 ... 31.6 VDC (Protection against polarity reversal)
AS-i Current consumption, maximum
100 mA

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing | non-icing
Protection class
II

Mechanical data - Connection technique

Termination
Connector plug M12, 4-pole, (A-coding)

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Holding force
1,000 N
Latching force
5 N
Actuating speed, maximum
2 m/s

Approvals - Standards

Certificates
TÜV | cULus | ASi-SaW

Electrical data - Auxiliary voltage

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Current consumption
500 mA
Rated operating voltage
24 VDC

Status indication

Note (LED switching conditions display)
(1) LED green: Supply voltage | (2) red LED: Communication error / Slave address = 0 | (3) LED yellow : Enabling status