Schmersal
101212664
SLC 421-E/R0490-30-RFBC
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Electrical data
- Switching voltage OSSD, HIGH signal
- 24 V
- Electrical power consumption of the receiver
- 8 W
- Electrical power consumption of the transmitter
- 4 W
- Wiring / Connector of external control unit
- Connector plug M8, 6-pole
Note
- Note (General)
- I | In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.
- Note (Clock control)
- 1 cycle or 2 cycles
Mechanical data - Dimensions
- Diameter of sensor
- 49 mm
- Height of sensor
- 708 mm
Scope of delivery
- Scope of delivery
- Emitter + receiver, mounting angle
General data - Features
- Clock control possible
- Yes
- Restart interlock (manual reset)
- Yes
- Contactor control integrated
- Yes
- Beam coding available
- Yes
- Blanking function
- Yes
- Integral system diagnostics, status
- Yes
- Integral system diagnostics
- Yes
- Number of beams
- 24
- Number of fail-safe digital outputs
- 2
- Wave length of the sensor
- 880 nm
General data
- Standards
- EN IEC 61496-2 | EN IEC 61496-1
- Enclosure material
- Aluminium
- Gross weight
- 2,720 g
- Reaction time, maximum
- 15 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 7.42 x 10⁻⁹ /h
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
- Safety type in accordance with IEC 61496-1
- 4
Electrical data - Safety digital outputs
- Output current, (fail-safe output), maximum
- 0.5 A
- Design of control elements
- p-type
Ambient conditions
- Degree of protection
- IP67
- Ambient temperature
- -10 ... +50 °C
- Storage and transport temperature, minimum
- -20 °C
- Storage and transport temperature, maximum
- +70 °C
- Protection class
- III
Mechanical data - Connection technique
- Termination
- Connector
- Terminal connector, Recipient
- Connector plug M12, 12-pole
- Terminal, Connector, Transmitter
- Connector plug M12, 4-pole
- Length of the connectable cable, maximum
- 100 m
Mechanical data
- Detection ability for test bodies at v = 1.6 m/s
- 30 mm
- Height of the protection field
- 490 mm
- Range, protection field, minimum
- 300 mm
- Range, protection field, maximum
- 7,000 mm
Accessory
- Recommended safety switchgear
- SCR 211
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories