Schmersal

101212893

EX-ZQ 900-13-3D
101212893
101212893
101212893
101212893
101212893
101212893
101212893
101212893
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Explosion protection

Explosion protection: regulations
EN IEC 60079-0 | EN IEC 60079-31
Explosion protection zones
22
Explosion protection category
3D
Explosion protection designation
II 3D Ex tc IIIC T100°C Dc
Manufacturer declaration
Manufacturer declaration | ATEX Zone 22

Electrical data

Thermal test current
4 A
Utilisation category AC-15
230 VAC
Utilisation category AC-15
4 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
1 A
Switching element
NO contact, NC contact
Switching principle
Snap action
Material of the contacts, electrical
Silver

Note

Note (General)
For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. | Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. | As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner.

Mechanical data - Dimensions

Length of sensor
57 mm
Width of sensor
71.5 mm
Height of the Sensor, minimum
221 mm
Height of the Sensor, maximum
237 mm

Ambient conditions - Insulation values

Rated insulation voltage U
500 V
Rated impulse withstand voltage U
6 kV

Scope of delivery

Scope of delivery
Including Ex-certified screwed cable gland and screw plug

Safety classification - Safety outputs

B
100,000 Operations

General data - Features

Number of auxiliary contacts
1
Number of safety contacts
3

General data

Standards
EN ISO 13850 | EN IEC 60947-5-1 | EN IEC 60947-5-5
Enclosure material
Metal, zinc die-cast
Enclosure coating material
painted
Material of the housing cover
Steel
Length of the wire, maximum
75 m
Gross weight
1,500 g

Safety classification

Standards
EN ISO 13849-1
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP67
Ambient temperature
-20 ... +55 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %

Mechanical data - Connection technique

Termination
Screw terminals M20 x 1.5
Cable cross-section of the cable glands, minimum
7 mm
Cable cross-section of the cable glands, maximum
12 mm
Cable section, minimum
0.75 mm²
Cable section, maximum
2.5 mm²
Note (Cable section)
All indications including the conductor ferrules.

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Actuating force, maximum
200 N
Actuating travel
400 mm