Electrical data - Safety digital inputs

Designation, Safety inputs
X1 and X2
Current consumption of the safety inputs
5 mA
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1 | C2 | C3

Electrical data

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Operating current, minimum
0.5 mA
No-load supply current I
35 mA
Rated operating voltage
24 VDC
Operating current
600 mA
Required rated short-circuit current
100 A
Time to readiness, maximum
2,000 ms
Switching frequency, maximum
1 Hz

Note

Note (General)
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary.

Mechanical data - Dimensions

Length of sensor
22 mm
Width of sensor
106.3 mm
Height of sensor
25 mm

Pin assignment

PIN 1
1A1 Ue: (1)
PIN 2
X1 Safety input 1
PIN 3
A2 GND Blue
PIN 4
Y1 Safety output 1 Black
PIN 5
OUT Diagnostic output OUT Grey
PIN 6
X2 Safety input 2 violet
PIN 7
Y2 Safety output 2 red
PIN 8
IN without function Pink

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Diagnostic output
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Cascadable
Yes
Integral system diagnostics, status
Yes
Number of LEDs
3
Number of semi-conductor outputs with signaling function
1
Number of fail-safe digital outputs
2

General data

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Universal coding
Coding level according to EN ISO 14119
Low
Working principle
RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m
Housing construction form
Block
Installation conditions (mechanical)
not flush
Sensor topology
Sensor for series wiring
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Active area
Glass-fibre, reinforced thermoplastic
Gross weight
250 g
Reaction time, maximum
100 ms
Duration of risk, maximum
200 ms
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs, maximum
0.5 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
2.70 x 10⁻¹⁰ /h
PFD value
2.10 x 10⁻⁵
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Designation, Safety outputs
Y1 and Y2
Rated operating current (safety outputs)
250 mA
Output current, (fail-safe output), maximum
0.25 A
Design of control elements
short-circuit proof, p-type
Voltage drop U
1 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse interval, typical
1000 ms
Test pulse duration, maximum
0.3 ms
Classification ZVEI CB24I, Source
C2
Classification ZVEI CB24I, Sink
C1 | C2

Ambient conditions

Degree of protection
IP65 | IP67 | IP69
Ambient temperature
-25 ... +70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Material temperature resistance of the cable (in motion), minimum
-10 °C
Material temperature resistance of the cable (at rest), minimum
-30 °C
Relative humidity, maximum
93 %
Note (Relative humidity)
non-condensing | non-icing
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Cable (Y-UL 2517), 8-pole
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Length of cable
2 m
Cable section, maximum
8 x 0.35 mm²
Wire cross-section
22 AWG
Cable type
LiYY

Electrical data - Diagnostic outputs

Designation, Diagnostic outputs
OUT
Design of control elements
short-circuit proof, p-type
Voltage drop U
2 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Switch distance, typical
12 mm
Assured switching distance "ON" S
10 mm
Assured switching distance "OFF" S
16 mm

Mechanical data

Actuating panels
lateral
Active area
lateral
Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
Actuating speed < 0.25 m/s | Operations for door weights ≤ 5 kg
Hysteresis (Switching distance), maximum
2 mm
Repeat accuracy R
0.5 mm
Note (Repeat accuracy R)
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance between two sensor systems 100 mm.
Mounting
A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.
Type of the fixing screws
2x M4 (cylinder head screws with washers DIN 125A / form A)
Tightening torque of the fixing screws, minimum
2.2 Nm
Tightening torque of the fixing screws, maximum
2.5 Nm

Accessory

Recommendation (actuator)
RST 36-1 | RST 36-1-R
Recommended safety switchgear
PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 60947-3

Status indication

Note (LED switching conditions display)
LED yellow: Operating condition | LED green: Supply voltage | LED red: Fault