Schmersal

101215715

MZM 120 B ST2-SD2PRE-A
101215715
101215715
101215715
101215715
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Electrical data - Safety digital inputs

Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Current consumption at 24 V
5 mA

Electrical data - Serial diagnostic SD

Designation, Serial diagnostic SD
OUT
Operation current
150 mA
Design of control elements
short-circuit proof, p-type
Wiring capacitance
50 nF

Electrical data

No-load supply current I
600 mA
Operating current
1,000 mA
Time to readiness, maximum
4,000 ms
Switching frequency, approx.
1 Hz

Note

Note (General)
As long as the safety guard remains closed, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.

Mechanical data - Dimensions

Length of sensor
40 mm
Width of sensor
40 mm
Height of sensor
177.5 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT serial diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN serial diagnostic input
PIN 9
without function

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Electrical data - Magnet control

Switching thresholds
-3 V … 5 V (Low) | 15 V … 30 V (High)
Magnet switch-on time
100 %

General data - Features

Power to lock
Yes
Actuator monitored
Yes
Serial diagnostics
Yes
Latching
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of safety contacts
2

General data

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Working principle
inductive
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
150 g
Reaction time, maximum
150 ms
Duration of risk, maximum
150 ms

Safety classification

Standards
EN IEC 60947-5-3 | EN IEC 61508
PFH value
4.30 x 10⁻⁹ /h
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Rated operating current (safety outputs)
250 mA
Voltage drop U
1 V
Leakage current I
0.5 mA

Safety classification - Interlocking function

Performance Level, up to
e
Category
4
Safety Integrity Level (SIL), suitable for applications in
3

Ambient conditions

Degree of protection
IP67 | IP69K
Ambient temperature
-25 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing | non-icing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Connector plug M12, 8-pole
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Electrical data - Diagnostic outputs

Voltage drop U
2 V

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
Operations for door weights ≤ 5 kg
Holding force
500 N
Latching force, minimum
30 N
Latching force, maximum
80 N

Accessory

Recommendation (actuator)
MZM 120-B1.1

Approvals - Standards

Certificates
cULus

Status indication

Note (LED switching conditions display)
Operating condition: LED green | Error / functional defect: LED red | Supply voltage U | available: LED green