Schmersal

101216187

AZM 161ST-11/12RI-024G-B1
101216187
101216187
101216187
101216187
101216187
101216187
101216187
101216187
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data

Thermal test current
6 A
Rated control voltage
24 VAC/DC
Required rated short-circuit current
1,000 A
Electrical power consumption, maximum
10 W
Switching element
NO contact, NC contact
Switching principle
slow action, positive break NC contact
Switching frequency
1,000 /h
Material of the contacts, electrical
Silver

Note

Note (General)
The axis of the hinge must be 5 mm above and in a parallel plane to the top surface of the safety switch. | minimum actuating radius on hinged guards in line with the plane of the actuator 150 mm | minimum actuating radius on rotating guard systems via the narrow edge of the actuator 180 mm | The actuator is not available separately.
Note (Manual release)
For maintenance, installation, etc. | For manual release using M5 triangular key, available as accessory

Mechanical data - Dimensions

Length of sensor
30 mm
Width of sensor
130 mm
Height of sensor
90 mm

Ambient conditions - Insulation values

Rated insulation voltage U
250 VAC
Rated impulse withstand voltage U
4 kV

Electrical data - Safety contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
2.5 A

Scope of delivery

Scope of delivery
Not available as spare part | Slot sealing plugs | The actuator is included in the scope of delivery

Safety classification - Safety outputs

B
2,000,000 Operations
B
1,000,000 Operations
Note (B
at 10% I | and ohmic load

Electrical data - Magnet control

Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms

General data - Features

Power to unlock
Yes
Manual release
Yes
Integral system diagnostics, status
Yes
Number of actuating directions
3
Number of auxiliary contacts
2
Number of safety contacts
4

General data

Standards
EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-1
Coding
Individual coding
Coding level according to EN ISO 14119
High
Working principle
electromechanical
Enclosure material
Glass-fibre, reinforced thermoplastic
Material of the actuator
Stainless steel
Gross weight
465 g

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
2.5 A

Safety classification

Standards
EN ISO 13849-1
Mission time
20 Year(s)

Other data

Note (applications)
sliding safety guard | removable guard | hinged safety guard

Ambient conditions

Degree of protection
IP67
Ambient temperature
-30 ... +60 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Connector plug M12, 4-pole, (A-coding) | Connector plug M12, 8-pole, (A-coding)
Cable section, minimum
0.25 mm²
Cable section, maximum
1.5 mm²
Note (Cable section)
All indications including the conductor ferrules.

Mechanical data

Actuating radius, minimum
150 mm
Mechanical life, minimum
1,000,000 Operations
Actuating play in direction of actuation
5.5 mm
Holding force F
2,000 N
Holding force F
2,600 N
Latching force
30 N
Positive break travel
10 mm
Positive break force per NC contact, minimum
10 N
Positive break force, minimum
20 N
Actuating speed, maximum
2 m/s
Type of the fixing screws
3x M6

Approvals - Standards

Certificates
cULus | CCC