Schmersal

101216735

SLC440-ER-0250-30-01
101216735
101216735
101216735
101216735
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data

Switching voltage OSSD, HIGH signal
24 V
Electrical power consumption of the receiver, maximum
10 W
Electrical power consumption of the transmitter, maximum
5 W

Note

Note (General)
I | In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.

Mechanical data - Dimensions

Height of transmitter
331 mm
Height of Receiver
341 mm
Length of sensor
33 mm
Width of sensor
27.8 mm

Scope of delivery

Scope of delivery
Kit with 2 mounting angles

General data - Features

Restart interlock (manual reset)
Yes
Contactor control integrated
Yes
Beam coding available
Yes
Blanking function
Yes
7-segment display
Yes
Integral system diagnostics, status
Yes
Integral system diagnostics
Yes
Bluetooth
Yes
Number of beams
12
Number of fail-safe digital outputs
2
Wave length of the sensor
880 nm

General data

Standards
EN IEC 61496-2 | EN IEC 61496-1
Enclosure material
Aluminium
Gross weight
630 g
Reaction time, maximum
10 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 62061
Performance Level, up to
e
Category
4
PFH value
5.14 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)
Safety type in accordance with IEC 61496-1
4

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum
0.25 A
Design of control elements
p-type

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +50 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Protection class
III

Mechanical data - Connection technique

Termination
Connector
Terminal connector, Recipient
Connector plug M12, 8-pole
Terminal, Connector, Transmitter
Connector plug M12, 4-pole
Length of the connectable cable, maximum
100 m

Mechanical data

Detection ability for test bodies at v = 1.6 m/s
30 mm
Height of the protection field
250 mm
Range, protection field, minimum
300 mm
Range, protection field, maximum
10,000 mm

Accessory

Recommended safety switchgear
SRB-E 301

Approvals - Standards

Certificates
TÜV | cULus

CAD Models

Trace parts
Trace parts
Download