Schmersal

101218030

PROTECT-SELECT-SK
101218030
101218030
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Electrical data - Safety digital inputs

Switching thresholds
-3 V … 2 V (LOW) | 18 V … 28.8 V
Current consumption at 24 V
6 mA

Electrical data

Operating voltage
12 VDC -10 % / +10 %
Current consumption at 24V, maximum
500 mA
No-load supply current I
500 mA
Rated operating voltage
12 VDC
Required rated short-circuit current
1,000 A
Note (Electrical data, Fuse rating)
slow blow
Switching frequency, maximum
0.1 Hz
Material of the contacts, electrical
Tin

Mechanical data - Dimensions

Width
52.5 mm
Height
100 mm
Depth
118 mm

Ambient conditions - Insulation values

Overvoltage category
III
Degree of pollution
2

General data - Features

Short circuit detection
Yes
Wire breakage detection
Yes
Cross-circuit detection
Yes
Removable Terminals
Yes
Start input
Yes
Feedback circuit
Yes
Automatic reset function
Yes
Reset edge detection
Yes
Start-up test
Yes
Earth connection detection
Yes
Integral system diagnostics, status
Yes
Integrated Display, Supply Voltage
Yes
Number of pulse outputs (test pulse output)
3
Number of relay outputs (1-channel)
2
Number of fail-safe analogue inputs
2
Number of digital fail-safe inputs
14
Number of digital fail-safe in-/outputs
4
Number of fail-safe digital outputs
4
Number of signalling outputs
4

General data

Standards
EN IEC 62061 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 61508 | EN IEC 60204-1 | EN IEC 60947-1
Climatic stress
EN 60068-2-1 | EN 60068-2-2 | EN 61496
Terminal (mechanical)
Removable screw terminals
Enclosure material
Polyamide / V0
Gross weight
300 g

Safety classification

Standards
EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 62061 | EN IEC 61508
Performance Level, up to
e
Category
4
Diagnostic Coverage (DC) Level
99
PFH value
1.78 x 10⁻⁸ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)
Common Cause Failure (CCF), minimum
65
Hardware fault tolerance (HFT)
1
Demand rate
high or continuous
Safe Failure Fraction (SFF), minimum
90
Notice
Valid for dual channel and 60% relay load
Performance Level, up to
d
Category
2
Safety Integrity Level (SIL), suitable for applications in
2

Electrical data - Safety digital outputs

Rated operating current (safety outputs)
700 mA
Design of control elements
short-circuit proof, p-type / n-type (Q0/0N and Q1/1N) | short-circuit proof, p-type (Q2 und Q3)
Leakage current I
2 mA

Other data

Note (applications)
Safety sensor | Guard system | Emergency-Stop button | Pull-wire emergency stop switches | Safety light curtain

Ambient conditions

Degree of protection
IP20
Degree of protection of the mounting space
IP54
Ambient temperature
-25 ... +55 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+75 °C
Relative humidity, minimum
15 %
Relative humidity, maximum
90 %
Note (Relative humidity)
non-condensing
Resistance to vibrations
10 … 57 Hz, amplitude 0.75 mm
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
rigid or flexible
Terminal designations
IEC 61131-2 | IEC/EN 60947-1
Cable section, minimum
0.25 mm²
Cable section, maximum
2.5 mm²
Tightening torque of Clips
0.6 Nm

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-1
250 VAC
Current, Utilisation category AC-1
4 A
Voltage, Utilisation category DC-1
24 VDC
Current, Utilisation category DC-1
4 A
Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
3 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Electrical data - Diagnostic outputs

Operating current
100 mA
Design of control elements
Limited short-circuit protection, p-type

Mechanical data

Mechanical life, minimum
10,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715

Specifications

Width
52.5 mm
Height
100 mm
Depth
118 mm

Approvals - Standards

Certificates
TÜV | cULus | CCC

Electrical data - Electromagnetic compatibility (EMC)

EMC rating
EMC-Directive