Schmersal

103001428

AZM300B-I2-ST-SD2P-A
103001428
103001428
103001428
103001428
103001428
103001428
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data - Safety digital inputs

Designation, Safety inputs
X1 and X2
Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Current consumption at 24 V
5 mA
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1 | C2 | C3

Electrical data - Serial diagnostic SD

Designation, Serial diagnostic SD
OUT
Operation current
150 mA
Design of control elements
short-circuit proof, p-type
Wiring capacitance
50 nF

Electrical data

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
No-load supply current I
100 mA
Current consumption with magnet ON, average
200 mA
Current consumption with magnet ON, peak
350 mA / 200 ms
Rated operating voltage
24 VDC
Required rated short-circuit current
100 A
External wire and device fuse rating
2 A gG
Time to readiness, maximum
5,000 ms
Switching frequency, maximum
0.5 Hz

Note

Note (General)
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. | For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.

Mechanical data - Dimensions

Length of sensor
120 mm
Width of sensor
87.5 mm
Height of sensor
35 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT serial diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN serial diagnostic input

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Electrical data - Magnet control

Designation, Magnet control
IN
Switching thresholds
-3 V … 5 V (Low) | 15 V … 30 V (High)
Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
40 ms
Classification ZVEI CB24I, Sink
C0
Classification ZVEI CB24I, Source
C1 | C2 | C3

General data - Features

Power to lock
Yes
Actuator monitored
Yes
Serial diagnostics
Yes
Latching
Yes
Manual release
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of actuating directions
3
Number of fail-safe digital outputs
2

General data

Standards
EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Individual coding, multiple teaching
Coding level according to EN ISO 14119
High
Working principle
RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
610 g
Duration of risk, maximum
200 ms
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs, maximum
1.5 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508

Electrical data - Safety digital outputs

Designation, Safety outputs
Y1 and Y2
Design of control elements
short-circuit proof, p-type
Voltage drop U
2 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse interval, typical
1000 ms
Test pulse duration, maximum
0.5 ms
Classification ZVEI CB24I, Source
C2
Classification ZVEI CB24I, Sink
C1 | C2

Safety classification - Interlocking function

Performance Level, up to
e
Category
4
PFH value
5.20 x 10⁻¹⁰ /h
PFD value
4.50 x 10⁻⁵
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP67 | IP69 | IP66
Ambient temperature
+0 ... +60 °C
Storage and transport temperature, minimum
-10 °C
Storage and transport temperature, maximum
+90 °C
Relative humidity, maximum
93 %
Note (Relative humidity)
non-condensing | non-icing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Connector M12, 8-pole, A-coded
Length of sensor chain, maximum
200 m
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Mechanical data - Switching distances according EN IEC 60947-5-3

Switch distance, typical
2 mm
Assured switching distance "ON" S
1 mm
Assured switching distance "OFF" S
20 mm

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
Angular misalignment between solenoid interlock and actuator, maximum
2 °
Holding force F
1,150 N
Holding force F
1,500 N
Latching force, adjustable, position 1
25 N
Latching force, adjustable, position 2
50 N
Type of the fixing screws
2x M6
Tightening torque of the fixing screws, minimum
6 Nm
Tightening torque of the fixing screws, maximum
7 Nm

Accessory

Recommendation (actuator)
AZ/AZM300-B1

Approvals - Standards

Certificates
TÜV | cULus | ECOLAB | FCC | IC

Status indication

Note (LED switching conditions display)
Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green

CAD Models

Trace parts
Trace parts
Download