103001462

AZ300-ST-1P2P
103001462
103001462
103001462
103001462
103001462
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

Electrical data - Safety digital inputs

Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Current consumption at 24 V
5 mA

Electrical data

Current consumption at 24V
5 mA
No-load supply current I
100 mA
Operating current
50 mA
Required rated short-circuit current
100 A
Time to readiness, maximum
5,000 ms
Switching frequency, approx.
0.5 Hz

Note

Note (General)
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. | For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.

Mechanical data - Dimensions

Length of sensor
35 mm
Width of sensor
85 mm
Height of sensor
100 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
without function

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.
Scope of delivery of mounting material
2 x M6

General data - Features

Actuator monitored
Yes
Latching
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of safety contacts
2

General data

Standards
EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Universal coding
Coding level according to EN ISO 14119
Low
Working principle
RFID
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
250 g
Reaction time, maximum
100 ms
Duration of risk, maximum
200 ms

Safety classification

Standards
EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
5.20 x 10⁻¹⁰ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Rated operating current (safety outputs)
250 mA
Voltage drop U
4 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A

Ambient conditions

Degree of protection
IP67 | IP69K | IP66
Ambient temperature
+0 ... +60 °C
Storage and transport temperature, minimum
-10 °C
Storage and transport temperature, maximum
+90 °C
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Connector M12, 8-pole, A-coded
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current

Electrical data - Diagnostic outputs

Design of control elements
short-circuit proof, p-type
Voltage drop U
4 V
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Switch distance, typical
2 mm
Assured switching distance "ON" S
1 mm
Assured switching distance "OFF" S
20 mm

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
> 50,000 operations for door weights ≤ 5 kg | Actuating speed ≤ 0.5 m/s
Latching force, adjustable, position 1
25 N
Latching force, adjustable, position 2
50 N

Accessory

Recommendation (actuator)
AZ/AZM300-B1

Approvals - Standards

Certificates
TÜV | cULus | ECOLAB | FCC | IC

Status indication

Note (LED switching conditions display)
Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green