Schmersal
103002179
EX-BNS 40S-12ZG-C 10,0M
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Additional Information
- Part Number
- 103002179
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Magnetic proximity switch
- Class Code : EC002544
- Version : 7
Explosion protection
- Explosion protection: regulations
- EN IEC 60079-0 | EN IEC 60079-15 | EN IEC 60079-31
- Explosion protection zones
- 22 | 2
- Explosion protection category
- 3D | 3G
- Explosion protection designation
- II 3G Ex nA nC IIC T6 Gc | II 3D Ex tc IIIC T80°C Dc X
- Manufacturer declaration
- Manufacturer declaration | ATEX Zone 2 and 22
Electrical data
- Required rated short-circuit current
- 100 A
- Switching voltage, maximum
- 24 VDC
- Switching current, maximum
- 0.01 A
- Switching capacity, maximum
- 0.2 W
- Switching frequency, maximum
- 5 Hz
Note
- Note (General)
- Contact symbols shown for the closed condition of the guard device. | The contact configuration for versions with or without LED is identical.
Mechanical data - Dimensions
- Length of sensor
- 14.5 mm
- Width of sensor
- 88 mm
- Height of sensor
- 27 mm
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
Safety classification - Safety outputs
- B
- 25,000,000 Operations
Electrical data - Digital Output
- Design of control elements
- Miscellaneous, Reed contacts
General data - Features
- Coding
- Yes
- Short circuit detection
- Yes
- Cross-circuit detection
- Yes
- Concealed, threaded holes on the back
- Yes
- Integral system diagnostics, general
- Yes
- Prerequisite evaluation unit
- Yes
- Number of normally closed (NC)
- 2
- Number of normally open (NO)
- 1
General data
- Standards
- EN IEC 60947-5-3
- Housing construction form
- Block
- Installation conditions (mechanical)
- not flush
- Enclosure material
- Stainless steel (V4A)
- Gross weight
- 644 g
Safety classification
- Standards
- EN ISO 13849-1
- Mission time
- 20 Year(s)
Wiring example
- Note (Wiring diagram)
- Contact S21-S22 must be integrated in the safety circuit.
Ambient conditions
- Degree of protection
- IP65 | IP67
- Ambient temperature
- -20 ... +60 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +80 °C
- Resistance to vibrations
- 10 … 55 Hz, amplitude 1 mm
- Restistance to shock
- 30 g / 11 ms
Mechanical data - Connection technique
- Termination
- Cable
- Length of cable
- 10 m
- Wire cross-section
- 0.25 mm
- Wire cross-section
- 23 AWG
- Material of the Cable mantle
- LiYY
Mechanical data - Switching distances according EN IEC 60947-5-3
- Assured switching distance "ON" S
- 8 mm
- Assured switching distance "OFF" S
- 18 mm
Mechanical data
- Active area
- lateral
- Actuating element
- Magnet
- Impact energy, maximum
- 7 J
- Direction of motion
- Head-on to the active surface
Accessory
- Recommendation (actuator)
- BPS 40S-2 | BPS 40S-1-C | BPS 40S-2-C
- Recommended safety switchgear
- SRB-E-301ST | SRB-E-201LC
Status indication
- Note (Integral System Diagnostics, status )
- The LED is illuminated when the guard is closed.
Other Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories