Schmersal

103003015

EX-CSS 8-16-2P+D-M-L-3G/D
103003015
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Explosion protection

Explosion protection: regulations
EN IEC 60079-0 | EN IEC 60079-15 | EN IEC 60079-31
Explosion protection zones
22 | 2
Explosion protection category
3D | 3G
Explosion protection designation
II 3G Ex nA IIB T6 Gc X | II 3D Ex tc IIIC T80°C Dc X
Manufacturer declaration
Manufacturer declaration | ATEX Zone 2 and 22

Electrical data

Operating voltage
24 VDC -15 % / +10 %
No-load supply current I
50 mA
Rated operating voltage
24 VDC
Operating current
500 mA
Switching frequency, approx.
3 Hz

Note

Note (General)
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.25 ms. Short-circuit recognition by the evaluation is not necessary.

Mechanical data - Dimensions

Length of sensor
39.5 mm
Width of sensor
55 mm
Height of sensor
93 mm

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Electrical data - Digital Output

Design of control elements
p-type

General data - Features

Short circuit detection
Yes
Cross-circuit detection
Yes
Safety functions
Yes
Cascadable
Yes
Integral system diagnostics, status
Yes
Number of semi-conductor outputs with signaling function
1
Number of fail-safe digital outputs
2
Number of series-wiring of sensors
16

General data

Working principle
inductive
Housing construction form
Block
Installation conditions (mechanical)
not flush
Sensor topology
Sensor for series wiring | Individual sensor or end sensor in a series
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Active area
Glass-fibre, reinforced thermoplastic
Gross weight
278 g
Reaction time, maximum
30 ms
Duration of risk, maximum
30 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
6.10 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Design of control elements
p-type
Voltage drop U
0.5 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.5 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.5 A

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
-25 ... +50 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Cable
Length of cable
2 m
Terminal connector, Input/Output
7-pole
Wire cross-section
0.25 mm
Wire cross-section
23 AWG

Electrical data - Diagnostic outputs

Voltage drop U
4 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Switch distance, typical
8 mm
Assured switching distance "ON" S
6 mm
Assured switching distance "OFF" S
11 mm

Mechanical data

Hysteresis (Switching distance), maximum
1 mm
Repeat accuracy R
0.5 mm

Accessory

Recommendation (actuator)
CST 16-1

Status indication

Note (LED switching conditions display)
Multi-coloured LED: Green, Red, Yellow