Schmersal
103003588
AZM400Z-ST2-2P2P-E
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Electrical data
- Operating voltage
- 24 VDC -15 % / +10 % (stabilised PELV power supply)
- Current consumption, maximum
- 600 mA
- No-load supply current I
- 100 mA
- Rated operating voltage
- 24 VDC
- Operating current
- 50 mA
- Required rated short-circuit current
- 100 A
- External wire and device fuse rating
- 2 A gG
- Time to readiness, maximum
- 1,500 ms
- Switching frequency, maximum
- 0.3 Hz
- Open / close cycle (motor), minimum
- 3
- Minimal average cycle time (with continuous operation)
- 20 s
Mechanical data - Dimensions
- Length of sensor
- 46.7 mm
- Width of sensor
- 77.8 mm
- Height of sensor
- 156.7 mm
Pin assignment
- Connection
- Connector 1
- PIN 1
- OUT2 Diagnostic output 2
- PIN 2
- E1 Control input 1
- PIN 3
- n.c.
- PIN 4
- Y1 Safety output 1
- PIN 5
- OUT1 Diagnostic output 1
- PIN 6
- E3 Control input 3
- PIN 7
- Y2 Safety output 2
- PIN 8
- E2 Control input 2
- Connection
- Connector 2
- PIN 1
- A1 Supply voltage UB
- PIN 2
- H2 GND
- PIN 3
- A2 GND
- PIN 4
- H1 Auxiliary voltage Uhe
- PIN 5
- FE (functional earth connection)
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
General data - Features
- Solenoid interlock monitored
- Yes
- Electronic manual release
- Yes
- Manual release
- Yes
- Short circuit detection
- Yes
- Cross-circuit detection
- Yes
- Safety functions
- Yes
- Integral system diagnostics, status
- Yes
- Number of diagnostic signals
- 2
- Number of safety contacts
- 2
General data
- Standards
- EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
- Coding
- Universal coding
- Coding level according to EN ISO 14119
- Low
- Working principle
- Magnetic field | RFID
- Frequency band RFID
- 125 kHz
- Transmitter output RFID, maximum
- -6 dB/m
- Enclosure material
- Light alloy die-casting
- Gross weight
- 692 g
- Reaction time, switching off safety outputs via actuator, maximum
- 100 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 61508
Electrical data - Safety digital outputs
- Designation, Safety outputs
- Y1 and Y2
- Rated operating current (safety outputs)
- 250 mA
- Design of control elements
- short-circuit proof, p-type
- Voltage drop U
- 2 V
- Leakage current I
- 0.5 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.25 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
- Test pulse interval, typical
- 1000 ms
- Test pulse duration, maximum
- 0.5 ms
- Classification ZVEI CB24I, Source
- C2
- Classification ZVEI CB24I, Sink
- C1 | C2
Safety classification - Interlocking function
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 1.00 x 10⁻⁹ /h
- PFD value
- 9.00 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - Control inputs Guard locking function
- Switching thresholds of the control inputs
- −3 V … 5 V (Low) | 15 V … 30 V (High)
- Classification ZVEI CB24I, Sink
- C0
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
- Current consumption at 24V, minimum
- 5 mA
- Current consumption at 24V, maximum
- 10 mA
- Allowable discrepancy time (input), maximum
- 10 s
Ambient conditions
- Degree of protection
- IP67 | IP66
- Ambient temperature
- -20 ... +55 °C
- Storage and transport temperature, minimum
- -40 °C
- Storage and transport temperature, maximum
- +85 °C
- Relative humidity, maximum
- 93 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations
- 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- III
- Permissible installation altitude above sea level, maximum
- 2,000 m
Mechanical data - Connection technique
- Termination
- 2 connector M12, 8 and 5 pin., both A-coded
Electrical data - Diagnostic outputs
- Designation, Diagnostic outputs
- OUT1 / OUT2
- Design of control elements
- short-circuit proof, p-type
- Voltage drop U
- 2 V
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.05 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.05 A
- Note
- The diagnostic output are not safety relevant outputs!
Safety classification - Guard locking function
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 1.80 x 10⁻⁹ /h
- PFD value
- 1.60 x 10⁻⁴
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Mechanical data
- Interlocking principle
- bistable
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical life)
- Which have a lateral force Ftrans = 100 N: 100.000 operations
- Angular misalignment between solenoid interlock and actuator, maximum
- 2 °
- Minimum distance devices
- 30 mm
- Holding force F
- 10,000 N
- Holding force F
- 13,000 N
- Lateral force at bolt return, maximal (against locked door)
- 300 N
- Note (Lateral force at bolt return)
- Does not apply to emergency exit, Bowden cable and manual release
- Type of the fixing screws
- 2x M6
- NOTE_DESIGN_MOUNTING_SCREW
- Property class min. 10.9
- Tightening torque of the screw
- 8 Nm
Accessory
- Recommendation (actuator)
- AZM400-B1
Approvals - Standards
- Certificates
- TÜV | cULus | FCC | IC
Status indication
- Note (LED switching conditions display)
- Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green
CAD Models
Trace parts
DownloadOther Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories