Electrical data - Fail-safe digital outputs
- Rated operating current (safety outputs)
- 250 mA
- Voltage drop U
- 2 V
- Current leakage I
- 1.5 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.25 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
- Classification ZVEI CB24I, Source
- C2
- Classification ZVEI CB24I, Sink
- C1 | C2
Safety appraisal - Guard locking
- Performance level, up to
- e
- Control category
- 4
- PFH-value
- 1.80 x 10⁻⁹ /h
- PFD value
- 1.60 x 10⁻⁴
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission Time
- 20 Year(s)
Safety appraisal
- Standards
- IEC 61508 | EN ISO 13849-1
Electrical data
- Operating Current
- 100 mA
- Current consumption, maximum
- 600 mA
- Current consumption at 24V, minimum
- 10 mA
- Current consumption at 24V, maximum
- 15 mA
- No-load supply current I
- 100 mA
- Rated operating voltage
- 24 VDC
- Operating current
- 50 mA
- Required rated short-circuit current to EN 60947-5-1
- 100 A
- Switching frequency, approx.
- 0.3 Hz
- Open / close cycle (Motor), minimum
- 3
- Minimal average cycle time (with continuous operation)
- 20 s
Electrical data - Fail-safe digital inputs
- Classification ZVEI CB24I, Sink
- C1
Safety appraisal - Interlocking
- Performance level, up to
- e
- Control category
- 4
- PFH-value
- 1.00 x 10⁻⁹ /h
- PFD value
- 9.00 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission Time
- 20 Year(s)
Mechanical data - Dimensions
- Length of sensor
- 46.7 mm
- Width of sensor
- 77.8 mm
- Height of sensor
- 166.7 mm
Electrical data - Control inputs
- Switching thresholds of the control inputs
- −3 V … 5 V (Low) | 15 V … 30 V (High)
- Allowable discrepancy time (input), maximum
- 10 s
- Classification ZVEI CB24I, Sink
- C0
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
Pin assignment
- Connection
- Connector 1
- PIN 1
- A1 Supply voltage UB
- PIN 2
- E1 Control input 1
- PIN 3
- n.c.
- PIN 4
- Y1 Safety output 1
- PIN 5
- OUT1 Diagnostic output 1
- PIN 6
- E3 Control input 3
- PIN 7
- Y2 Safety output 2
- PIN 8
- E2 Control input 2
- Connection
- Connector 2
- PIN 2
- H2 GND
- PIN 3
- A2 GND
- PIN 4
- H1 Auxiliary voltage Uhe
- PIN 5
- FE (functional earth connection)
Scope of delivery
- Included in delivery
- Actuators must be ordered separately.
- Delivery scope of Mounting material
- 2 x M6 (10.9)
Ambient conditions - Insulation value
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution to VDE 0100
- 3
General data - Features
- Guard locking monitored
- Yes
- Electronic manual release
- Yes
- Manual release
- Yes
- Short circuit detection
- Yes
- Short-circuit recognition
- Yes
- Safety functions
- Yes
- Integral System Diagnostics, status
- Yes
- Number of diagnostic signals
- 2
- Number of safety contacts
- 2
General data
- Standards
- IEC 60947-5-1 | EN ISO 13849-1 | IEC 61508 | EN ISO 14119
- General information
- Individual coding
- Coding level according to ISO 14119
- High
- Active principle
- Magnetic field | RFID
- Enclosure material
- Light alloy die-casting
- Gross weight
- 692 g
- Time to readiness, maximum
- 1,500 ms
- Reaction time, maximum
- 100 ms
Ambient conditions
- Degree of protection
- IP66 to EN 60529 | IP67 to EN 60529
- Ambient temperature, minimum
- -20 °C
- Ambient temperature, maximum
- +55 °C
- Storage and transport temperature, minimum
- -40 °C
- Storage and transport temperature, maximum
- +85 °C
- Resistance to vibrations to EN 60068-2-6
- 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection rating
- III
Electrical data - Diagnostic output
- Versions
- short-circuit proof, p-type
- Voltage drop U
- 2 V
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.05 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.05 A
- Note
- The diagnostic output are not safety relevant outputs!
Mechanical data - Connection technique
- Terminal Connector
- 2 connector M12, 8 and 5 pin
Mechanical data
- Interlocking principle
- bistable
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical lifetime)
- Which have a lateral force Ftrans = 100 N: 100.000 operations
- Minimum distance devices
- 30 mm
- Clamping force in accordance with EN ISO 14119 F
- 10,000 N
- Clamping force, maximum F
- 13,000 N
- Lateral force at bolt return, maximal (against locked door)
- 300 N
- Note (Lateral force at bolt return)
- Does not apply to emergency exit, Bowden cable and manual release
- Tightening torque of the screw
- 8 Nm
Accessory
- Recommendation (actuator)
- AZM400-B1
Approval - Standards
- Certificates
- TÜV | cULus | EAC | FCC | IC
Status indication
- Note (LED switching conditions display)
- Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green
CAD Models
Trace parts
DownloadOther Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories