Schmersal

103003840

AZM400Z-ST-I1-1P2P-T
103003840
103003840
103003840
103003840
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Current consumption, maximum
600 mA
No-load supply current I
100 mA
Rated operating voltage
24 VDC
Operating current
50 mA
Required rated short-circuit current
100 A
External wire and device fuse rating
2 A gG
Time to readiness, maximum
1,500 ms
Switching frequency, maximum
0.3 Hz
Open / close cycle (motor), minimum
3
Minimal average cycle time (with continuous operation)
20 s

Mechanical data - Dimensions

Length of sensor
65.3 mm
Width of sensor
77.8 mm
Height of sensor
156.7 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
X2 Safety input 2
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
E3 Control input 3
PIN 7
Y2 Safety output 2
PIN 8
E2 Control input 2

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Solenoid interlock monitored
Yes
Emergency exit
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of diagnostic signals
1
Number of safety contacts
2

General data

Standards
EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Individual coding
Coding level according to EN ISO 14119
High
Working principle
Magnetic field | RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m
Enclosure material
Light alloy die-casting
Gross weight
846 g
Reaction time, switching off safety outputs via actuator, maximum
100 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508

Electrical data - Safety digital outputs

Designation, Safety outputs
Y1 and Y2
Rated operating current (safety outputs)
250 mA
Design of control elements
short-circuit proof, p-type
Voltage drop U
2 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse interval, typical
1000 ms
Test pulse duration, maximum
0.5 ms
Classification ZVEI CB24I, Source
C2
Classification ZVEI CB24I, Sink
C1 | C2

Safety classification - Interlocking function

Performance Level, up to
e
Category
4
PFH value
1.00 x 10⁻⁹ /h
PFD value
9.00 x 10⁻⁵
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Control inputs Guard locking function

Switching thresholds of the control inputs
−3 V … 5 V (Low) | 15 V … 30 V (High)
Classification ZVEI CB24I, Sink
C0
Classification ZVEI CB24I, Source
C1 | C2 | C3
Current consumption at 24V, minimum
5 mA
Current consumption at 24V, maximum
10 mA
Allowable discrepancy time (input), maximum
10 s

Ambient conditions

Degree of protection
IP67 | IP66
Ambient temperature
-20 ... +55 °C
Storage and transport temperature, minimum
-40 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, maximum
93 %
Note (Relative humidity)
non-condensing | non-icing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Connector M12, 8-pole, A-coded

Electrical data - Diagnostic outputs

Designation, Diagnostic outputs
OUT
Design of control elements
short-circuit proof, p-type
Voltage drop U
2 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A
Note
The diagnostic output are not safety relevant outputs!

Safety classification - Guard locking function

Performance Level, up to
e
Category
4
PFH value
1.80 x 10⁻⁹ /h
PFD value
1.60 x 10⁻⁴
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Mechanical data

Interlocking principle
bistable
Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
Which have a lateral force Ftrans = 100 N: 100.000 operations
Angular misalignment between solenoid interlock and actuator, maximum
2 °
Minimum distance devices
30 mm
Holding force F
10,000 N
Holding force F
13,000 N
Lateral force at bolt return, maximal (against locked door)
300 N
Note (Lateral force at bolt return)
Does not apply to emergency exit, Bowden cable and manual release
Type of the fixing screws
2x M6
NOTE_DESIGN_MOUNTING_SCREW
Property class min. 10.9
Tightening torque of the screw
8 Nm

Accessory

Recommendation (actuator)
AZM400-B1

Approvals - Standards

Certificates
TÜV | cULus | FCC | IC

Status indication

Note (LED switching conditions display)
Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green

CAD Models

Trace parts
Trace parts
Download