Schmersal

103004339

RSS16-I2-D-ST8H
103004339
103004339
103004339
103004339
103004339
103004339
103004339
103004339
103004339
103004339
103004339
103004339
103004339
103004339
103004339
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
1084,53 zł
1
Payment methods:

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)
1,000 mA
Output current, (fail-safe output), maximum
1 A
Versions
p-type
Voltage drop U
1 V
Current leakage I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
1 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
1 A

Safety appraisal

Standards
EN ISO 13849-1 | IEC 60947-5-3 | EN 62061 | IEC 61508
Performance level, up to
e
Control category to EN13849
4
PFH-value
6.30 x 10⁻¹¹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission Time
20 Year(s)

Electrical data

Voltage type
DC (direct current)
No-load supply current I
100 mA
Rated operating voltage, minimum
20.4 VDC
Rated operating voltage, maximum
26.4 VDC
Operating current
2,100 mA
Required rated short-circuit current to EN 60947-5-1
100 A
Switching frequency, approx.
1 Hz

Mechanical data - Dimensions

Length of sensor
91 mm
Width of sensor
52 mm
Height of sensor
30 mm

Scope of delivery

Included in delivery
Actuators must be ordered separately.

Ambient conditions - Insulation value

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution to VDE 0100
3

General data - Features

Diagnostic output
Yes
Short circuit detection
Yes
Short-circuit recognition
Yes
Series-wiring
Yes
Safety functions
Yes
Cascadable
Yes
Integral System Diagnostics, status
Yes
Number of LEDs
2
Number of semi-conductor outputs with signaling function
1
Number of fail-safe digital outputs
2

General data

Standards
IEC 60947-5-3
General information
Individual coding, multiple teaching
Coding level according to ISO 14119
High
Active principle
RFID
Housing construction form
Block
Installation conditions (mechanical)
not flush
Sensor topology
Sensor for series wiring
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Active area
Glass-fibre, reinforced thermoplastic
Gross weight
275 g
Time to readiness, maximum
2,000 ms
Reaction time, maximum
100 ms
Duration of risk, maximum
200 ms

Ambient conditions

Degree of protection
IP65 to EN 60529 | IP66 to EN 60529 | IP67 to EN 60529
Ambient temperature, minimum
-25 °C
Ambient temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Restistance to shock
30 g / 11 ms
Protection rating
0

Electrical data - Diagnostic output

Operating current
50 mA
Versions
p-type
Voltage drop U
2 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Connection technique

Terminal Connector
Connector M12, 8-pole
Note
The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance
15 mm
Ensured switch distance "ON" S
12 mm
Ensured switch distance "OFF" S
30 mm

Mechanical data

Actuating panels
front side | rear | from head
Active area
lateral | front side | cover-side
Hysteresis (Switch distance), maximum
2 mm
Repeat accuracy R R
0.5 mm
Mounting
2 x M5, Cylinder head screw
Tightening torque of nuts, maximum
2 Nm

Accessory

Recommendation (actuator)
RST16-1 | RST-U-2
Recommended safety switchgear
PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 60947-3

Approval - Standards

Certificates
TÜV | cULus | EAC | FCC | IC

Status indication

Note (LED switching conditions display)
Multi-coloured LED: Green, Red | LED yellow: Operating condition | LED green: Supply voltage | LED red: Fault

CAD Models

Trace parts
Trace parts
Download