Schmersal

103004640

RSS260-I1-ST-AS
103004640
103004640
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data

Time to readiness, maximum
2,000 ms
Switching frequency, maximum
1 Hz

Electrical data - AS-Interface specification

AS-i Specification
Safety-Slave
AS-i Version
V 2.1
AS-i Profile
S-0.B.F.E
AS-i, IO-Code
0x0
AS-i, ID-Code
0xB
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0 … DO 3
No Function
AS-i Parameter bits, P0
Actuator in
AS-i Parameter bits, P1
Enabling inhibit (tamper protection time) active (FID))
AS-i Parameter bits, P2
No function
AS-i Parameter bits, P3
Internal device error (FID)
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Mechanical data - Dimensions

Length of sensor
18 mm
Width of sensor
40 mm
Height of sensor
29.5 mm

Pin assignment

PIN 1
AS-Interface +
PIN 2
n.c. (≤ 30 VDC)
PIN 3
AS-Interface -
PIN 4
n.c. (≤ 30 VDC)

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.
Note (scope of delivery, number and type)
Actuator incl. mounting plate

General data - Features

Coding
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of actuating directions
2

General data

Standards
EN IEC 62026-2 | EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Individual coding
Coding level according to EN ISO 14119
High
Working principle
RFID
Enclosure material
Thermoplastic hotmelt
Gross weight
55 g
Reaction time, maximum
100 ms
Duration of risk, maximum
200 ms

Safety classification

Standards
EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
3.93 x 10⁻¹⁰ /h
PFD value
6.89 x 10⁻⁵
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - AS Interface

Rated operating voltage
18 ... 31.6 VDC (Protection against polarity reversal)
AS-i Current consumption, maximum
100 mA

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
-25 ... +60 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Protection class
III

Mechanical data - Connection technique

Termination
Connector M8, 4-pole, A-coded

Mechanical data - Switching distances according EN IEC 60947-5-3

Switching distance S
12 mm | 9 mm (in case of approach from side)
Assured switching distance "ON", frontal
10 mm
Assured switching distance "OFF", frontal
18 mm
Assured switching distance "ON", lateral
6 mm
Assured switching distance "OFF", lateral
15 mm

Mechanical data

Hysteresis (Switching distance), maximum
2 mm
Repeat accuracy R
0.5 mm

Accessory

Recommendation (actuator)
RST260-1

Approvals - Standards

Certificates
TÜV | cULus | ASi-SaW | FCC

Status indication

Note (LED switching conditions display)
(1) green/red LED (AS-i Duo LED):Supply voltage / communication error / slave address = 0 / periphery error detected / Tamper protection time active | (2) yellow LED: device condition (enabling status) / hysteresis signal / device error