Electrical data

Switching voltage OSSD, HIGH signal
24 V
Electrical power consumption of the receiver, maximum
10 W
Electrical power consumption of the transmitter, maximum
5 W

Note

Note (General)
I | In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.

Mechanical data - Dimensions

Length of sensor
33 mm
Width of sensor
27.8 mm
Height of the Sensor (Receiver)
261 mm
Height of the Sensor (Transmitter)
251 mm

Scope of delivery

Scope of delivery
Kit with 2 mounting angles

General data - Features

Muting function
Yes
Override
Yes
Clock control possible
Yes
Restart interlock (manual reset)
Yes
Contactor control integrated
Yes
Beam coding available
Yes
Blanking function
Yes
7-segment display
Yes
Integral system diagnostics, status
Yes
Integral system diagnostics
Yes
Reduced resolution
Yes
Number of beams
8
Number of fail-safe digital outputs
2
Wave length of the sensor
880 nm

General data

Standards
CLC/TS 61496-2 | EN IEC 61496-1
Enclosure material
Aluminium
Gross weight
580 g
Reaction time, maximum
10 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 62061
Performance Level, up to
e
Category
4
PFH value
5.14 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)
Safety type in accordance with IEC 61496-1
4

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum
0.25 A
Design of control elements
p-type

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +50 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Protection class
III

Mechanical data - Connection technique

Termination
Connector
Terminal connector, Recipient
Connector plug M12, 12-pole
Terminal, Connector, Transmitter
Connector plug M12, 4-pole
Length of the connectable cable, maximum
100 m

Mechanical data

Detection ability for test bodies at v = 1.6 m/s
30 mm
Height of the protection field
170 mm
Range, protection field, minimum
300 mm
Range, protection field, maximum
10,000 mm

Accessory

Recommended safety switchgear
SRB-E 301

Approvals - Standards

Certificates
TÜV | cULus

CAD Models

Trace parts