Schmersal
103005908
AZM300B-I1-ST-AS-A-P
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Additional Information
- Part Number
- 103005908
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Position switch with guard locking
- Class Code : EC002593
- Version : 7
Electrical data
- Time to readiness, maximum
- 5,000 ms
Electrical data - AS-Interface specification
- AS-i Specification
- Safety-Slave
- AS-i Version
- V 3.0
- AS-i Profile
- S-7.B.F.E
- AS-i Input, Channel 1
- Data bits DI 0 / DI 1 = dynamic code transmission
- AS-i Input, Channel 2
- Data bits DI 2 / DI 3 = dynamic code transmission
- AS-i Outputs, DO 0
- Solenoid control
- AS-i Outputs, DO 1
- No Function
- AS-i Outputs, DO 2
- No Function
- AS-i Outputs, DO 3
- No Function
- AS-i Parameter bits, P0
- Safety guard closed and can be locked
- AS-i Parameter bits, P1
- Solenoid interlock locked
- AS-i Parameter bits, P2
- Auxiliary voltage in
- AS-i Parameter bits, P3
- Internal device error (FID)
- Note (AS-i Parameter bits)
- Set the parameter outputs to "1111" (0xF) | FID: periphery error
- AS-i Input module address
- 0
- Note (AS-i Input module address)
- Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note
- Note (General)
- For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. | For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
Mechanical data - Dimensions
- Length of sensor
- 120 mm
- Width of sensor
- 87.5 mm
- Height of sensor
- 35 mm
Pin assignment
- PIN 1
- AS-Interface +
- PIN 2
- Aux - (P)
- PIN 3
- AS-Interface -
- PIN 4
- Aux + (P)
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
Electrical data - Magnet control
- Magnet switch-on time
- 100 %
General data - Features
- Power to lock
- Yes
- Actuator monitored
- Yes
- Latching
- Yes
- Manual release
- Yes
- Safety functions
- Yes
- Integral system diagnostics, status
- Yes
- Number of actuating directions
- 3
General data
- Standards
- EN IEC 62026-2 | EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
- Coding
- Individual coding
- Coding level according to EN ISO 14119
- High
- Working principle
- RFID
- Frequency band RFID
- 125 kHz
- Transmitter output RFID, maximum
- -6 dB/m
- Enclosure material
- Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Gross weight
- 595 g
- Reaction time, maximum
- 120 ms
- Duration of risk, maximum
- 200 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 61508
Electrical data - AS Interface
- Rated operating voltage
- 18 ... 31.6 VDC (Protection against polarity reversal)
- AS-i Current consumption, maximum
- 100 mA
Safety classification - Interlocking function
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 4.00 x 10⁻¹⁰ /h
- PFD value
- 7.00 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Ambient conditions
- Degree of protection
- IP67 | IP69 | IP66
- Ambient temperature
- +0 ... +60 °C
- Storage and transport temperature, minimum
- -10 °C
- Storage and transport temperature, maximum
- +90 °C
- Relative humidity, maximum
- 93 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations
- 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- III
- Permissible installation altitude above sea level, maximum
- 2,000 m
Mechanical data - Connection technique
- Termination
- Connector plug M12, 4-pole, (A-coding)
Mechanical data - Switching distances according EN IEC 60947-5-3
- Switch distance, typical
- 2 mm
- Assured switching distance "ON" S
- 1 mm
- Assured switching distance "OFF" S
- 20 mm
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical life)
- When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
- Angular misalignment between solenoid interlock and actuator, maximum
- 2 °
- Holding force F
- 1,150 N
- Holding force F
- 1,500 N
- Latching force, adjustable, position 1
- 25 N
- Latching force, adjustable, position 2
- 50 N
- Type of the fixing screws
- 2x M6
- Tightening torque of the fixing screws, minimum
- 6 Nm
- Tightening torque of the fixing screws, maximum
- 7 Nm
Accessory
- Recommendation (actuator)
- AZ/AZM300-B1
Approvals - Standards
- Certificates
- TÜV | cULus | ASi-SaW | ECOLAB | FCC
Electrical data - Auxiliary voltage
- Operating voltage
- 24 VDC -15 % / +10 % (stabilised PELV power supply)
- Current consumption
- 300 mA
- Rated operating voltage
- 24 VDC
Status indication
- Note (LED switching conditions display)
- (1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address = 0/periphery error detected/device error detected/manipulation protection active | (2) LED yellow: Device condition (Enabling status) | (3) LED red: Internal device error
CAD Models
Trace parts
DownloadOther Categories
NanometersManometersFlowmetersSensorsAcceleration SensorsFiber Optic SensorsDetectorsUltrasonic SensorsTemperature & Humidity SensorsVibration SensorsLevel SensorsPressure SensorsProximity SensorsInductive SensorsMotion SensorsMagnetic Sensors GroupOptical SensorsCapacitive SensorsPhotoelectric SensorsPosition SensorsEncodersOther sensors and Accessories