Schmersal

103005922

AZM300Z-I1-ST-AS-P
103005922
103005922
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data

Time to readiness, maximum
5,000 ms

Electrical data - AS-Interface specification

AS-i Specification
Safety-Slave
AS-i Version
V 3.0
AS-i Profile
S-7.B.F.E
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0
Solenoid control
AS-i Outputs, DO 1
No Function
AS-i Outputs, DO 2
No Function
AS-i Outputs, DO 3
No Function
AS-i Parameter bits, P0
Safety guard closed and can be locked
AS-i Parameter bits, P1
Solenoid interlock locked
AS-i Parameter bits, P2
Auxiliary voltage in
AS-i Parameter bits, P3
Internal device error (FID)
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Note

Note (General)
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. | For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.

Mechanical data - Dimensions

Length of sensor
120 mm
Width of sensor
87.5 mm
Height of sensor
35 mm

Pin assignment

PIN 1
AS-Interface +
PIN 2
Aux - (P)
PIN 3
AS-Interface -
PIN 4
Aux + (P)

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Electrical data - Magnet control

Magnet switch-on time
100 %

General data - Features

Power to unlock
Yes
Solenoid interlock monitored
Yes
Latching
Yes
Manual release
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of actuating directions
3

General data

Standards
EN IEC 62026-2 | EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Individual coding
Coding level according to EN ISO 14119
High
Working principle
RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
618 g
Reaction time, maximum
120 ms
Duration of risk, maximum
200 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508

Electrical data - AS Interface

Rated operating voltage
18 ... 31.6 VDC (Protection against polarity reversal)
AS-i Current consumption, maximum
100 mA

Safety classification - Interlocking function

Performance Level, up to
e
Category
4
PFH value
4.00 x 10⁻¹⁰ /h
PFD value
7.00 x 10⁻⁵
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP67 | IP69 | IP66
Ambient temperature
+0 ... +60 °C
Storage and transport temperature, minimum
-10 °C
Storage and transport temperature, maximum
+90 °C
Relative humidity, maximum
93 %
Note (Relative humidity)
non-condensing | non-icing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Connector plug M12, 4-pole, (A-coding)

Mechanical data - Switching distances according EN IEC 60947-5-3

Switch distance, typical
2 mm
Assured switching distance "ON" S
1 mm
Assured switching distance "OFF" S
20 mm

Safety classification - Guard locking function

Performance Level, up to
e
Note (Performance Level)
Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions.

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
Angular misalignment between solenoid interlock and actuator, maximum
2 °
Holding force F
1,150 N
Holding force F
1,500 N
Latching force, adjustable, position 1
25 N
Latching force, adjustable, position 2
50 N
Type of the fixing screws
2x M6
Tightening torque of the fixing screws, minimum
6 Nm
Tightening torque of the fixing screws, maximum
7 Nm

Accessory

Recommendation (actuator)
AZ/AZM300-B1

Approvals - Standards

Certificates
TÜV | cULus | ASi-SaW | ECOLAB | FCC

Electrical data - Auxiliary voltage

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Current consumption
300 mA
Rated operating voltage
24 VDC

Status indication

Note (LED switching conditions display)
(1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address = 0/periphery error detected/device error detected/manipulation protection active | (2) LED yellow: Device condition (Enabling status) | (3) LED red: Internal device error

CAD Models

Trace parts
Trace parts
Download