Schmersal

103007444

SLC440AS-ER-0330-14
103007444
103007444
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data - AS-Interface specification

AS-i Specification
Safety-Slave
AS-i Version
V 3.0
AS-i Profile
S-0.B.F.E
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0 … DO 3
No Function
AS-i Parameter bits, P0
No function
AS-i Parameter bits, P1
Low beam quality
AS-i Parameter bits, P2
No function
AS-i Parameter bits, P3
Internal device error (FID)
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF) | FID: periphery error
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Mechanical data - Dimensions

Height of Receiver
463 mm
Length of sensor
33 mm
Width of sensor
27.8 mm
Height of the Sensor (Transmitter)
443 mm

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
2

General data - Features

Safety functions
Yes
Blanking function
Yes
7-segment display
Yes
Integral system diagnostics, status
Yes
Number of beams
32
Wave length of the sensor
880 nm

General data

Standards
CLC/TS 61496-2 | EN 50295 | EN IEC 62061 | EN ISO 13849-1 | EN IEC 61496-1
Working principle
optoelectronic
Enclosure material
Aluminium
Gross weight
730 g
Reaction time, maximum
13 ms

Safety classification

Standards
EN IEC 62061
Performance Level, up to
e
Category
4
PFH value
5.17 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)
Safety type in accordance with IEC 61496-1
4

Electrical data - AS Interface

Rated operating voltage
18 ... 31.6 VDC (Protection against polarity reversal)
AS-i Current consumption, maximum
50 mA

Ambient conditions

Degree of protection
IP67
Ambient temperature
-10 ... +50 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10 … 55 Hz, amplitude 0.35 mm
Restistance to shock
10 g / 16 ms
Protection class
III

Mechanical data - Connection technique

Termination
Connector
Terminal connector, Recipient
Connector plug M12, 5-pole
Terminal, Connector, Transmitter
Connector plug M12, 4-pole

Mechanical data

Detection ability for test bodies at v = 1.6 m/s
14 mm
Height of the protection field
330 mm
Range, protection field, minimum
300 mm
Range, protection field, maximum
7,000 mm

Approvals - Standards

Certificates
TÜV | cULus | ASi-SaW

Electrical data - Auxiliary voltage

Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Power consumption, Receiver
150 mA
Power consumption, Transmitter
75 mA
Rated operating voltage
24 VDC

Status indication

Note (LED switching conditions display)
Green/red LED (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected

CAD Models

Trace parts
Trace parts