Schmersal
103009970
SRB-E-201LC
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
€171.81
1
Payment methods:
A total of 41 Parts In-Stock from 5 Distributors
Product Conditions:
Electrical data
- Operating voltage
- 24 VDC -20 % / +20 %
- Ripple voltage
- 10 %
- Rated operating voltage
- 24 VDC
- Operating current
- 100 mA
- Rated AC voltage for controls at DC minimum
- 19.2 VDC
- Rated control voltage at DC, maximum
- 28.8 VDC
- Electrical power consumption
- 2.4 W
- Drop-out delay in case of power failure, typically
- 10 ms
- Drop-out delay in case of emergency, typically
- 10 ms
- Pull-in delay at automatic start, maximum, typically
- 150 ms
- Pull-in delay at RESET, typically
- 150 ms
- Switching frequency, maximum
- 1 Hz
Mechanical data - Dimensions
- Width
- 22.5 mm
- Height
- 98 mm
- Depth
- 115 mm
Ambient conditions - Insulation values
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 2
Electrical data - Digital Output
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.1 A
General data - Features
- Stop-Category
- 0
- Electronic Fuse
- Yes
- Wire breakage detection
- Yes
- Cross-circuit detection
- Yes
- Removable Terminals
- Yes
- Start input
- Yes
- Feedback circuit
- Yes
- Automatic reset function
- Yes
- Reset edge detection
- Yes
- Earth connection detection
- Yes
- Integral system diagnostics, status
- Yes
- Integral system diagnostics, error code
- Yes
- Number of LEDs
- 5
- Number of normally closed (NC)
- 2
- Number of normally open (NO)
- 1
- Number of safety digital outputs, Stop 0
- 2
- Number of signalling outputs
- 1
General data
- Standards
- EN IEC 62061 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 60947-5-5 | EN IEC 61508 | EN IEC 60204-1 | EN IEC 60947-1
- Climatic stress
- EN 60068-2-78
- Enclosure material
- Glass-fibre reinforced thermoplastic, ventilated
- Gross weight
- 130 g
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 62061 | EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 2.66 x 10⁻⁹ /h
- PFD value
- 2.42 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - Safety digital outputs
- Voltage drop U
- 0.5 V
- Leakage current I
- 1 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 2 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 2 A
Other data
- Note (applications)
- Safety sensor | hinged safety guard | Emergency-Stop button | Pull-wire emergency stop switches | Safety light curtain
Ambient conditions
- Degree of protection of the enclosure
- IP40
- Degree of protection of the mounting space
- IP54
- Degree of protection of clips or terminals
- IP20
- Ambient temperature
- -25 ... +60 °C
- Storage and transport temperature, minimum
- -40 °C
- Storage and transport temperature, maximum
- +85 °C
- Resistance to vibrations
- 10 ... 55 Hz, Amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
Mechanical data - Connection technique
- Termination
- rigid or flexible | Screw connection, plug-in
- Terminal designations
- IEC/EN 60947-1
- Cable section, minimum
- 0.25 mm²
- Cable section, maximum
- 2.5 mm²
- Tightening torque of Clips
- 0.5 Nm
Mechanical data
- Mounting
- Snaps onto standard DIN rail to EN 60715
Specifications
- Width
- 22.5 mm
- Height
- 98 mm
- Depth
- 115 mm
Approvals - Standards
- Certificates
- TÜV | cULus | CCC
Electrical data - Electromagnetic compatibility (EMC)
- EMC rating
- EMC-Directive
Electrical data - Digital inputs
- Conduction resistance, maximum
- 40 Ω
Status indication
- Indicated operating states
- Internal operating voltage U | Baustein-Status | Fault codes
CAD Models