Schmersal

103014405

ZV14H 236 ST-AS
103014405
103014405
103014405
103014405
103014405
103014405
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Electrical data

Current consumption
50 mA
Thermal test current
10 A
Utilisation category AC-15
240 VAC
Utilisation category AC-15
4 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
1 A
Switching element
Opener (NC)
Switching principle
Snap action
Switching frequency
5,000 /h
Material of the contacts, electrical
Silver

Electrical data - AS-Interface specification

AS-i Version
V 3.0
AS-i Profile
S-0.B.F.F
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0 … DO 3
No Function
AS-i Parameter bits, P0
Channel 2 switched
AS-i Parameter bits, P1 ... P3
No function
AS-i Input module address
0
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Mechanical data - Dimensions

Length of sensor
46 mm
Width of sensor
30 mm
Height of sensor
127.5 mm

Pin assignment

PIN 1
AS-Interface +
PIN 2
n.c.
PIN 3
AS-Interface -
PIN 4
n.c.
PIN 5
Functional earth connection

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV

General data - Features

Safety functions
Yes
Integral system diagnostics, status
Yes
Number of auxiliary contacts
0
Number of safety contacts
2

General data

Standards
EN 50295 | EN ISO 13849-1 | EN IEC 60947-5-1 | EN IEC 61508
Housing construction form
Norm construction design
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Lever material
Metal film
Gross weight
107 g

Safety classification

Standards
EN IEC 61508
Performance Level, up to
c
Category
1
PFH value
1.14 x 10⁻⁶ /h
Note (PFH-value)
up to max. 100,000 switching cycles/year
Safety Integrity Level (SIL), suitable for applications in
1
Mission time
20 Year(s)
Please note:
Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende Beschädigung der 1-kanaligen Mechanik zulässig ist und ein ausreichender Manipulationsschutz gewährleistet ist.
Performance Level, up to
d
Category
3
PFH value
1.01 x 10⁻⁷ /h
Safety Integrity Level (SIL), suitable for applications in
2

Electrical data - AS Interface

Rated operating voltage
18 ... 31.6 VDC (Protection against polarity reversal)

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +60 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing | non-icing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm / 5 g
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Connector plug M12, 4-pole
Material of the connector (electrical)
Plastic

Mechanical data

Actuating element
Roller lever
Roller material
Plastic
Mechanical life, minimum
1,000,000 Operations
Actuating speed, maximum
1 m/s
Actuating torque, minimum
0.2 Nm
Positive break torque
0.2 Nm

Status indication

Note (LED switching conditions display)
(1) LED yellow: Channel 1 / AS-i SaW Bit 0.1 | (2) LED green-red (AS-i Duo LED):Supply voltage / Communication error / Slave address = 0 | (3) LED yellow: Channel 2 / AS-i SaW Bit 2.3