Schmersal

103014732

RSS260-I2-D-LSTM12-8-0,25M
103014732
103014732
103014732
103014732
103014732
103014732
103014732
103014732
103014732
103014732
103014732
103014732
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data - Fail-safe digital outputs

Versions
p-type
Voltage drop U
1 V
Current leakage I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A

Safety appraisal

Standards
EN ISO 13849-1 | IEC 60947-5-3 | EN 62061 | IEC 61508
Performance level, up to
e
Control category to EN13849
4
PFH-value
6.80 x 10⁻¹⁰ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission Time
20 Year(s)

Electrical data

Voltage type
DC (direct current)
No-load supply current I
100 mA
Rated operating voltage
24 VDC -15% / +10%
Rated operating voltage, minimum
20.4 VDC
Rated operating voltage, maximum
26.4 VDC
Operating current
600 mA
Required rated short-circuit current to EN 60947-5-1
100 A
Switching frequency, approx.
1 Hz

Mechanical data - Dimensions

Length of sensor
29.5 mm
Width of sensor
39.2 mm
Height of sensor
18 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
without function

Ambient conditions - Insulation value

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution to VDE 0100
3

General data - Features

Short circuit detection
Yes
Short-circuit recognition
Yes
Safety functions
Yes
Number of poles
8

General data

Standards
IEC 60947-5-3
General information
Individual coding, multiple teaching
Coding level according to ISO 14119
High
Active principle
RFID
Housing construction form
Block
Installation conditions (mechanical)
not flush
Enclosure material
Plastic, thermoplastic, self-extinguishing
Active area
Glass-fibre, thermoplastic
Gross weight
161 g
Time to readiness, maximum
2,000 ms
Reaction time, maximum
100 ms
Duration of risk, maximum
200 ms

Ambient conditions

Degree of protection
IP65 to EN 60529 | IP67 to EN 60529
Ambient temperature, minimum
-25 °C
Ambient temperature, maximum
+65 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations to EN 60068-2-6
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms

Electrical data - Diagnostic output

Operating current
50 mA
Versions
p-type
Voltage drop U
2 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Connection technique

Terminal Connector
Connector M8, 8-pole
Note
The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Switching distances according IEC 60947-5-3

Ensured switching distance "ON", front
10 mm
Ensured switching distance "OFF", front
18 mm
Ensured switching distance "ON", side
6 mm
Ensured switch distance "OFF" S
15 mm

Mechanical data

Actuating panels
lateral | front side
Active area
lateral | front
Hysteresis (Switch distance), maximum
2 mm
Repeat accuracy R R
0.5 mm
Mounting
A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws.

Accessory

Recommendation (actuator)
RST16-1 | RST-U-2 | RST260-1

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 60947-3

Approval - Standards

Certificates
TÜV | cULus | EAC | FCC | IC

Status indication

Note (LED switching conditions display)
(1) LED green: Supply voltage | LED yellow: Operating condition | LED red: Fault

CAD Models

Trace parts
Trace parts
Download