103039218
EX-AZM300Z-I2-ST-1P2P-CL
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Electrical data - Safety digital inputs
- Designation, Safety inputs
- X1 and X2
- Switching thresholds
- −3 V … 5 V (Low) | 15 V … 30 V (High)
- Current consumption at 24 V
- 5 mA
- Test pulse duration, maximum
- 1 ms
- Test pulse interval, minimum
- 100 ms
- Classification ZVEI CB24I, Sink
- C1
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
Explosion protection
- Explosion protection: regulations
- EN IEC 60079-0 | EN IEC 60079-31 | EN IEC 60079-7
- Explosion protection zones
- 22 | 2
- Explosion protection category
- 3D | 3G
- Explosion protection designation
- D II 3G Ex ec IIB T5 Gc | II 3GD | EX tc IIIB T95°C Dc X
- Manufacturer declaration
- Manufacturer declaration | ATEX Zone 2 and 22
Electrical data
- No-load supply current I
- 100 mA
- Current consumption with magnet ON, average
- 200 mA
- Current consumption with magnet ON, peak
- 350 mA / 200 ms
- Rated operating voltage
- 24 VDC
- Operating current
- 50 mA
- Required rated short-circuit current
- 100 A
- External wire and device fuse rating
- 2 A gG
- Time to readiness, maximum
- 5,000 ms
- Switching frequency, maximum
- 0.5 Hz
Note
- Note (General)
- For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. | For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
Mechanical data - Dimensions
- Length of sensor
- 178 mm
- Width of sensor
- 93 mm
- Height of sensor
- 35 mm
Pin assignment
- PIN 1
- A1 Supply voltage UB
- PIN 2
- X1 Safety input 1
- PIN 3
- A2 GND
- PIN 4
- Y1 Safety output 1
- PIN 5
- OUT Diagnostic output
- PIN 6
- X2 Safety input 2
- PIN 7
- Y2 Safety output 2
- PIN 8
- IN Solenoid control
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
Electrical data - Magnet control
- Designation, Magnet control
- IN
- Switching thresholds
- -3 V … 5 V (Low) | 15 V … 30 V (High)
- Current consumption at 24 V
- 10 mA
- Magnet switch-on time
- 100 %
- Test pulse duration, maximum
- 5 ms
- Test pulse interval, minimum
- 40 ms
- Classification ZVEI CB24I, Sink
- C0
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
General data - Features
- Power to unlock
- Yes
- Solenoid interlock monitored
- Yes
- Latching
- Yes
- Manual release
- Yes
- Short circuit detection
- Yes
- Cross-circuit detection
- Yes
- Series-wiring
- Yes
- Safety functions
- Yes
- Integral system diagnostics, status
- Yes
- Number of actuating directions
- 1
- Number of fail-safe digital outputs
- 2
General data
- Standards
- EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-1 | EN IEC 60947-5-3 | EN IEC 61508
- Coding
- Individual coding, multiple teaching
- Coding level according to EN ISO 14119
- High
- Working principle
- RFID
- Frequency band RFID
- 125 kHz
- Transmitter output RFID, maximum
- -6 dB/m
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Material of the fixing screws
- Stainless steel (V4A)
- Gross weight
- 1,137 g
- Duration of risk, maximum
- 200 ms
- Reaction time, switching off safety outputs via actuator, maximum
- 100 ms
- Reaction time, switching off safety outputs via safety inputs, maximum
- 1.5 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 62061 | EN IEC 61508
Electrical data - Safety digital outputs
- Designation, Safety outputs
- Y1 and Y2
- Rated operating current (safety outputs)
- 250 mA
- Design of control elements
- short-circuit proof, p-type
- Voltage drop U
- 2 V
- Leakage current I
- 0.5 mA
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.25 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
- Test pulse interval, typical
- 1000 ms
- Test pulse duration, maximum
- 0.5 ms
- Classification ZVEI CB24I, Source
- C2
- Classification ZVEI CB24I, Sink
- C1 | C2
Safety classification - Interlocking function
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 5.20 x 10⁻¹⁰ /h
- PFD value
- 4.50 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Ambient conditions
- Degree of protection
- IP67 | IP69 | IP66
- Ambient temperature
- +0 ... +50 °C
- Storage and transport temperature, minimum
- -10 °C
- Storage and transport temperature, maximum
- +90 °C
- Relative humidity, maximum
- 93 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations
- 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- III
- Permissible installation altitude above sea level, maximum
- 2,000 m
Mechanical data - Connection technique
- Termination
- Connector M12, 8-pole, A-coded
- Length of sensor chain, maximum
- 200 m
- Note (length of the sensor chain)
- Cable length and cross-section change the voltage drop dependiing on the output current
- Note (series-wiring)
- Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Electrical data - Diagnostic outputs
- Designation, Diagnostic outputs
- OUT
- Voltage drop U
- 2 V
- Voltage, Utilisation category DC-12
- 24 VDC
- Current, Utilisation category DC-12
- 0.05 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.05 A
Mechanical data - Switching distances according EN IEC 60947-5-3
- Switch distance, typical
- 2 mm
- Assured switching distance "ON" S
- 1 mm
- Assured switching distance "OFF" S
- 20 mm
Safety classification - Guard locking function
- Performance Level, up to
- d
- Category
- 2
- PFH value
- 2.00 x 10⁻⁹ /h
- PFD value
- 1.80 x 10⁻⁴
- Safety Integrity Level (SIL), suitable for applications in
- 2
- Mission time
- 20 Year(s)
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical life)
- When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
- Angular misalignment between solenoid interlock and actuator, maximum
- 2 °
- Impact energy, maximum
- 7 J
- Holding force F
- 1,150 N
- Holding force F
- 1,500 N
- Latching force, adjustable, position 1
- 25 N
- Latching force, adjustable, position 2
- 50 N
- Type of the fixing screws
- 2x M6
- Tightening torque of the fixing screws, maximum
- 8 Nm
Accessory
- Recommendation (actuator)
- EX-AZ/AZM300-B1
Approvals - Standards
- Certificates
- TÜV
Status indication
- Note (LED switching conditions display)
- Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green