Schmersal

103045522

EX-BNS 250-11Z-3GD
103045522
103045522
103045522
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Explosion protection

Explosion protection: regulations
EN IEC 60079-0 | EN IEC 60079-15 | EN IEC 60079-31
Explosion protection zones
22 | 2
Explosion protection category
3D | 3G
Explosion protection designation
II 3G Ex nC IIC T6 Gc X | II 3D Ex tc IIIC T80°C Dc X
Manufacturer declaration
Manufacturer declaration | Additional simple electrical apparatus (Zone 0 and 20)

Electrical data

Switching voltage, maximum
24 VDC
Switching current, maximum
0.1 A
Switching capacity, maximum
1 W
Switching frequency, maximum
5 Hz

Note

Note (General)
Contact symbols shown for the closed condition of the guard device. | The contact configuration for versions with or without LED is identical.

Mechanical data - Dimensions

Length of sensor
13 mm
Width of sensor
33 mm
Height of sensor
25 mm

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Safety classification - Safety outputs

B
25,000,000 Operations

Electrical data - Digital Output

Design of control elements
Miscellaneous, Reed contacts

General data - Features

Coding
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Prerequisite evaluation unit
Yes
Number of normally closed (NC)
1
Number of normally open (NO)
1
Number of cable wires
4

General data

Housing construction form
Block
Installation conditions (mechanical)
not flush
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
101 g

Safety classification

Standards
EN ISO 13849-1
Mission time
20 Year(s)

Ambient conditions

Degree of protection
IP67
Ambient temperature
-25 ... +70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+70 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
Cable
Length of cable
1 m
Wire cross-section
0.25 mm
Wire cross-section
23 AWG
Material of the Cable mantle
PVC

Mechanical data - Switching distances according EN IEC 60947-5-3

Assured switching distance "ON" S
4 mm
Assured switching distance "OFF" S
14 mm

Mechanical data

Actuating element
Magnet
Impact energy, maximum
7 J
Direction of motion
Head-on to the active surface

Accessory

Recommendation (actuator)
EX-BPS 250-3G/D
Recommended safety switchgear
SRB-E-301ST | SRB-E-201LC