Schmersal

103046784

AZ201ST2-T-1P2P-DU
103046784
103046784
103046784
103046784
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data - Safety digital inputs

Designation, Safety inputs
X1 and X2
Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Current consumption at 24 V
5 mA
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1 | C2 | C3

Electrical data

Operating voltage
24 VDC -15 % / +10 %
No-load supply current I
50 mA
Rated operating voltage
24 VDC
Operating current
700 mA
Required rated short-circuit current
100 A
External wire and device fuse rating
2 A gG
Time to readiness, maximum
4,000 ms
Switching frequency, maximum
1 Hz

Mechanical data - Dimensions

Length of sensor
50 mm
Width of sensor
40 mm
Height of sensor
220 mm

Pin assignment

PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
n.c.

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of safety contacts
2

General data

Standards
EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
Coding
Universal coding
Coding level according to EN ISO 14119
Low
Working principle
RFID, 125 kHz
Transmitter output RFID, maximum
-6 dB/m
Enclosure material
Glass-fibre, reinforced thermoplastic
Duration of risk, maximum
200 ms
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs, maximum
0.5 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
1.90 x 10⁻⁹ /h
PFD value
1.60 x 10⁻⁴
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Designation, Safety outputs
Y1 and Y2
Rated operating current (safety outputs)
250 mA
Design of control elements
short-circuit proof, p-type
Voltage drop U
4 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse interval, typical
1000 ms
Test pulse duration, maximum
0.5 ms
Classification ZVEI CB24I, Source
C2
Classification ZVEI CB24I, Sink
C1 | C2

Ambient conditions

Degree of protection
IP67 | IP66
Ambient temperature
-25 ... +70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, maximum
93 %
Note (Relative humidity)
non-condensing | non-icing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level, maximum
2,000 m

Mechanical data - Connection technique

Termination
Connector M12, 8-pole
Length of sensor chain, maximum
200 m
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Electrical data - Diagnostic outputs

Designation, Diagnostic outputs
OUT
Operating current
50 mA
Design of control elements
short-circuit proof, p-type
Voltage drop U
4 V
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Assured switching distance "ON" S
4 mm
Assured switching distance "OFF" S
30 mm

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Hysteresis (Switching distance), maximum
1.5 mm
Repeat accuracy R
0.5 mm
Latching force
30 N
Actuating speed, maximum
0.2 m/s
Type of the fixing screws
2x M6
Tightening torque of the fastening screws for the housing cover, minimum
0.7 Nm
Tightening torque of the fastening screws for the housing cover, maximum
1 Nm
Note
Torx T10

Accessory

Recommendation (actuator)
AZ/AZM201-B1 | AZ/AZM201-B30

Approvals - Standards

Certificates
TÜV | cULus | FCC | IC

Status indication

Note (LED switching conditions display)
Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green