Schmersal

131013866

TZFL24VDC
131013866
131013866
131013866
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data

Thermal test current
4 A
Rated control voltage
24 VDC
Required rated short-circuit current
1,000 A
Electrical power consumption, maximum
8.5 W
Switching principle
Slow action
Material of the contacts, electrical
Silver

Mechanical data - Dimensions

Length of sensor
41 mm
Width of sensor
129 mm
Height of sensor
92.5 mm

Ambient conditions - Insulation values

Rated insulation voltage U
250 VAC
Rated impulse withstand voltage U
2.5 kV

Electrical data - Safety contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Scope of delivery

Scope of delivery
The actuator TZ/CO is included in delivery.

Safety classification - Safety outputs

B
2,000,000 Operations
B
1,000,000 Operations

General data - Features

Power to unlock
Yes
Integral system diagnostics, status
Yes
Number of actuating directions
4
Number of auxiliary contacts
1
Number of safety contacts
2

General data

Standards
BG-GS-ET-19 | EN IEC 60947-5-1
Coding level according to EN ISO 14119
Low
Working principle
electromechanical
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
480 g

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Safety classification

Standards
EN ISO 13849-1
Mission time
20 Year(s)

Other data

Note (applications)
sliding safety guard | removable guard | hinged safety guard

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
+0 ... +50 °C

Mechanical data - Connection technique

Termination
Screw terminals
Cable section, minimum
1 x 0.5 mm²
Cable section, maximum
1 x 1.5 mm²
Note (Cable section)
All indications including the conductor ferrules.

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Holding force F
1,500 N
Latching force
20 N
Positive break travel
3.5 mm
Positive break force, minimum
20 N
Actuating speed, maximum
0.3 m/s

CAD Models

Trace parts
Trace parts
Download