Schmersal

131030169

AZM190-11/01RKN-24VDC
131030169
131030169
131030169
131030169
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Electrical data

Thermal test current
4 A
Rated control voltage
24 VDC
Required rated short-circuit current
1,000 A
Electrical power consumption, maximum
8.5 W
Switching element
NO contact, NC contact
Switching principle
slow action, positive break NC contact
Switching frequency
1.2 /h
Material of the contacts, electrical
Silver

Note

Note (Manual release)
front
Note (Emergency release)
For cases of danger | Mounting only outside the guarded area

Mechanical data - Dimensions

Length of sensor
41 mm
Width of sensor
52 mm
Height of sensor
178 mm

Ambient conditions - Insulation values

Rated insulation voltage U
250 VAC
Rated impulse withstand voltage U
4 kV

Electrical data - Safety contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

Safety classification - Safety outputs

B
2,000,000 Operations
B
1,000,000 Operations

Electrical data - Magnet control

Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
50 ms

General data - Features

Power to unlock
Yes
Emergency release
Yes
Number of actuating directions
4
Number of auxiliary contacts
1 | 2
Number of cable glands
2
Number of safety contacts
1

General data

Standards
BG-GS-ET-19 | EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-1
Coding level according to EN ISO 14119
Low
Working principle
electromechanical
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
500 g

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Safety classification

Standards
EN ISO 13849-1
Mission time
20 Year(s)

Other data

Note (applications)
sliding safety guard | removable guard | hinged safety guard

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
+0 ... +50 °C

Mechanical data - Connection technique

Termination
Screw terminals
Cable entry
2 x M20 x 1,5
Cable section, minimum
0.5 mm²
Cable section, maximum
1.5 mm²
Note (Cable section)
All indications including the conductor ferrules.

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Holding force F
1,950 N
Holding force F
2,550 N
Latching force
20 N
Positive break force, minimum
20 N
Actuating speed, maximum
0.3 m/s

Approvals - Standards

Certificates
TÜV | cULus | CCC