Schmersal

133006276

AZM190-02/02RK-24VDC
133006276
133006276
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:

Safety appraisal

Standards
EN ISO 13849-1
Mission Time
20 Year(s)

Electrical data

Thermal test current
4 A
Rated control voltage
24 VDC
Required rated short-circuit current to EN 60947-5-1
1,000 A
Electrical power consumption, maximum
8.5 W
Switching element
Opener (NC)
Switching principle
Creep circuit element
Switching frequency
1.2 /h

Mechanical data - Dimensions

Length of sensor
41 mm
Width of sensor
52 mm
Height of sensor
178 mm

Electrical data - Safety contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Scope of delivery

Included in delivery
Actuators must be ordered separately.

Ambient conditions - Insulation value

Rated insulation voltage U
250 V
Rated impulse withstand voltage U
4 kV

Safety appraisal - Safety outputs

B10d Normally-closed contact (NC)
2,000,000 Operations
B10d Normally open contact (NO)
1,000,000 Operations

General data - Features

Power to unlock
Yes
Manual release
Yes
Number of actuating directions
4
Number of cable glands
2
Number of safety contacts
4

General data

Standards
EN 60947-5-1 | BG-GS-ET-19
Coding level according to ISO 14119
Low
Active principle
electromechanical
Enclosure material
Glass-fibre, reinforced thermoplastic
Material of the contacts, electrical
Silver
Gross weight
480 g

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15
230 VAC
Current, Utilisation category AC-15
4 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
4 A

Other data

Note (applications)
sliding safety guard | removable guard | hinged safety guard

Ambient conditions

Degree of protection
IP67 to EN 60529
Ambient temperature, minimum
+0 °C
Ambient temperature, maximum
+50 °C

Mechanical data - Connection technique

Terminal Connector
Screw terminals
Cable entry
M20 cable gland
Cable section, minimum
1 x 0.5 mm²
Cable section, maximum
1 x 1.5 mm²
Note (Cable section)
All indications about the cable section are including the conductor ferrules.

Mechanical data

Mechanical life, minimum
1,000,000 Operations
Clamping force
1,950 N
Latching force
20 N
Positive break force, minimum
20 N
Actuating speed, maximum
0.3 m/s

Approval - Standards

Certificates
TÜV | cULus | CCC | EAC