999999904
AZM161CC-12/12RKA-M16-24V
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Electrical data
- Thermal test current
- 6 A
- Rated control voltage
- 24 VAC/DC
- Required rated short-circuit current
- 1,000 A
- Electrical power consumption, maximum
- 10 W
- Switching element
- NO contact, NC contact
- Switching principle
- Slow action
- Switching frequency
- 1,000 /h
- Material of the contacts, electrical
- Silver
Note
- Note (Manual release)
- For maintenance, installation, etc. | For manual release using M5 triangular key, available as accessory
Mechanical data - Dimensions
- Length of sensor
- 30 mm
- Width of sensor
- 130 mm
- Height of sensor
- 90 mm
Ambient conditions - Insulation values
- Rated insulation voltage U
- 250 VAC
- Rated impulse withstand voltage U
- 4 kV
Electrical data - Safety contacts
- Voltage, Utilisation category AC-15
- 230 VAC
- Current, Utilisation category AC-15
- 4 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 2.5 A
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
Safety classification - Safety outputs
- B
- 2,000,000 Operations
- B
- 1,000,000 Operations
General data - Features
- Power to lock
- Yes
- Manual release
- Yes
- Number of actuating directions
- 3
- Number of auxiliary contacts
- 2
- Number of safety contacts
- 4
General data
- Standards
- BG-GS-ET-19 | EN ISO 14119 | EN IEC 60947-5-1
- Coding level according to EN ISO 14119
- Low
- Working principle
- electromechanical
- Enclosure material
- Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Gross weight
- 458 g
Electrical data - Auxiliary contacts
- Voltage, Utilisation category AC-15
- 230 VAC
- Current, Utilisation category AC-15
- 4 A
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 2.5 A
Safety classification
- Standards
- EN ISO 13849-1
- Mission time
- 20 Year(s)
Other data
- Note (applications)
- sliding safety guard | removable guard | hinged safety guard
Ambient conditions
- Degree of protection
- IP67
- Ambient temperature
- -30 ... +60 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
Mechanical data - Connection technique
- Termination
- Cage clamps
- Cable entry
- 4 x M16 x 1,5
- Cable section, minimum
- 1 x 0.25 mm²
- Cable section, maximum
- 1 x 1.5 mm²
- Note (Cable section)
- All indications including the conductor ferrules.
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Actuating play in direction of actuation
- 5.5 mm
- Holding force F
- 2,000 N
- Latching force
- 30 N
- Positive break travel
- 10 mm
- Positive break force, minimum
- 20 N
- Actuating speed, maximum
- 2 m/s
Approvals - Standards
- Certificates
- cULus | CCC