Electrical data

Operating voltage
24 VDC -15 % / +10 %
No-load supply current I
100 mA
Rated operating voltage
24 VDC
Operating current
600 mA
Required rated short-circuit current
100 A
Time to readiness, maximum
2,000 ms
Switching frequency, approx.
1 Hz

Mechanical data - Dimensions

Length of sensor
29.5 mm
Width of sensor
39.2 mm
Height of sensor
18 mm

Pin assignment

PIN 1
A1 U | : White
PIN 2
X1 safety input 1: Brown
PIN 3
A2 GND: Green
PIN 4
Y1 safety output 1: Yellow
PIN 5
OUT Diagnostic output OUT Grey
PIN 6
X2 safety input 2: Pink
PIN 7
Y2 safety output 2: Blue
PIN 8
IN without function: Red

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

General data - Features

Diagnostic output
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Safety functions
Yes
Cascadable
Yes
Integral system diagnostics, status
Yes
Number of LEDs
3
Number of semi-conductor outputs with signaling function
1
Number of fail-safe digital outputs
2

General data

Standards
EN IEC 60947-5-3
Coding
Universal coding
Coding level according to EN ISO 14119
Low
Working principle
RFID
Housing construction form
Block
Installation conditions (mechanical)
not flush
Sensor topology
Sensor for series wiring
Enclosure material
Plastic, thermoplastic, self-extinguishing
Active area
Glass-fibre, thermoplastic
Gross weight
47 g
Reaction time, maximum
100 ms
Duration of risk, maximum
200 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 62061 | EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
6.80 x 10⁻¹⁰ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Design of control elements
p-type
Voltage drop U
1 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
-25 ... +65 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms

Mechanical data - Connection technique

Termination
Connector M8
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current

Electrical data - Diagnostic outputs

Design of control elements
p-type
Voltage drop U
2 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A

Mechanical data - Switching distances according EN IEC 60947-5-3

Switching distance S
front 12 mm | lateral 9 mm
Assured switching distance "ON", frontal
10 mm
Assured switching distance "OFF", frontal
18 mm
Assured switching distance "ON", lateral
6 mm
Assured switching distance "OFF", lateral
15 mm

Mechanical data

Actuating panels
lateral | front side
Active area
lateral | front
Hysteresis (Switching distance), maximum
2 mm
Repeat accuracy R
0.5 mm
Note (Repeat accuracy R)
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum 100 mm clearance in case of approach from side.
Mounting
A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws.

Accessory

Recommendation (actuator)
RST16-1 | RST-U-2 | RST260-1
Recommended safety switchgear
PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC

Approvals - Standards

Certificates
TÜV | cULus | FCC | IC | UKCA

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 60947-3

Status indication

Note (LED switching conditions display)
LED yellow: Operating condition | LED green: Supply voltage | LED red: Fault