Specifications

Range Of Product
Modicon Quantum automation platform
Product Or Component Type
DIO drop interface

Contractual warranty

Warranty
18 months

Complementary

Connections - Terminals
terminal block, 7 poles
Minimum Load Current
0 A
I/O Words
30 I/32 O
Output Overvoltage Protection
with
Diagnostics Startup
checksum || RAM || RAM address
Typical Backplanes
2 positions || 3 positions || 6 positions || 16 positions || 4 positions || 10 positions
Maximum Buffer Time
1 ms
Short-Circuit Protection
with
Supply Voltage Limits
20-30 V
Power Dissipation In W
11 W
Maximum Supply Current
1.6 A 24 V
Nominal Output Current
3 A
Number Of Port
2 redundant
Diagnostics Run Time
checksum || RAM address || RAM
Output Voltage
5.1 V
Inrush Current
30 A 24 V
Module Format
standard
[Us] Rated Supply Voltage
24 V DC
Associated Fuse Rating
2.5 A

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP071201EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI0712001EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
GOST || C-tick || DNV || CSA Class 1 Division 2 || UL
Ambient Air Temperature For Operation
0-60 °C
Resistance To Electromagnetic Fields
10 V/m 80-2000 MHz IEC 801-3
Standards
UL 508
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
95-95 % without condensation
Resistance To Electrostatic Discharge
4 kV contact IEC 801-2 || 8 kV on air IEC 801-2
Protective Treatment
TC
Operating Altitude
<= 16404.2 ft (5000 m)