8 temperature sensor module MET148-2 for Sepam series 20, 40, 60, 80
59641
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Additional Information

Part Number
59641
UNSPSC
39122221

Specifications

Module Type
temperature sensor
Range Of Product
Sepam series 80 || Sepam series 60 || Sepam series 80 NPP || Sepam series 40 || Sepam series 20
Device Short Name
MET148-2

Complementary

Mechanical Robustness
earthquakes in operation 2) 1 Gn (vertical axes) IEC 60255-21-3 || earthquakes in operation 2) 2 Gn (horizontal axes) IEC 60255-21-3 || jolts de-energized 2) 20 Gn/16 ms IEC 60255-21-2 || shocks de-energized 2) 27 Gn/11 ms IEC 60255-21-2 || shocks in operation 2) 10 Gn/11 ms IEC 60255-21-2 || vibrations de-energized 2) 2 Gn, 10 Hz...150 Hz IEC 60255-21-1 || vibrations in operation 2) 1 Gn, 10 Hz...150 Hz IEC 60255-21-1 || vibrations in operation Fc) 2 Hz...13.2 Hz, a = +/- 1 mm IEC 60068-2-6
Height
88 mm
Mounting Mode
fixed
Maximum Distance Between Sensor And Module
1 km
Mounting Support
symmetrical DIN rail
Number Of Inputs
8
Temperature Probe Type
Ni 100/Ni 120, <4 mA none || Pt 100, <4 mA none
Type Of Measurement
Temperature
Auxiliary Connection Terminal
earthing terminal screw-type connectors cable <1000 m || earthing terminal screw-type connectors tinned copper braid 6-100 mm² <1000 m || RTDs screw-type connectors 1 wire 0.2-2.5 mm² || RTDs screw-type connectors 2 wire 0.2-1 mm²
Width
144 mm
Depth
30 mm
Tightening Torque
earthing terminal 2.2-2.2 N.m
Net Weight
0.2 kg

Offer Sustainability

China Rohs Regulation
X
Circularity Profile
ENVEOLI1411007
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1411007
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold

Environment

Ambient Air Temperature For Operation
-25-70 °C
Climatic Withstand
influence of corrosion/gaz test 2 in operation) 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 IEC 60068-2-60 || salt mist in operation) Kb/2 6 days IEC 60068-2-52 || temperature variation with specified variation rate in storage) Nb - 25 °C to 70 °C, 5 °C/min IEC 60068-2-14 || influence of corrosion/gaz test 4 in operation) 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 IEC 60068-2-60 || continuous exposure to damp heat in operation) Cab 10 days, 93 % RH, 40 °C IEC 60068-2-78 || continuous exposure to damp heat in storage) Cab 56 days, 93 % RH, 40 °C IEC 60068-2-78 || continuous exposure to damp heat in storage) Db 6 days, 95 % RH, 55 °C IEC 60068-2-30 || exposure to cold in operation) Ad - 25 °C IEC 60068-2-1 || exposure to cold in storage) Ab - 25 °C IEC 60068-2-1 || exposure to dry heat in operation) Bd 70 °C IEC 60068-2-2 || exposure to dry heat in storage) Bb 70 °C IEC 60068-2-2
Electromagnetic Compatibility
1 MHz damped oscillating wave 2.5 kV CM, 1 kV DM immunity tests-conducted disturbances) IEC 60255-22-1 || fast transient bursts 4kV, 2.5 kHz immunity tests-conducted disturbances) ANSI C37.90.1 || fast transient bursts 4kV, 2.5 kHz/2 kV, 5 kHz immunity tests-conducted disturbances) A and B IEC 60255-22-4 || fast transient bursts 4kV, 2.5 kHz immunity tests-conducted disturbances) IV IEC 61000-4-4 || immunity to conducted RF disturbances 10 V immunity tests-conducted disturbances) III IEC 60255-22-6 || immunity to magnetic fields at network frequency 30 A/m (continuous)-300 A/m (1-3 s) immunity tests-radiated disturbances) IV IEC 61000-4-8 || immunity to radiated fields 10 V/m, 80 MHz...1 GHz immunity tests-radiated disturbances) IEC 60255-22-3 || immunity to radiated fields 35 V/m, 25 MHz...1 GHz immunity tests-radiated disturbances) ANSI C37.90.2 || immunity to radiated fields 10 V/m, 80 MHz...2 GHz immunity tests-radiated disturbances) III IEC 61000-4-3 || surges 2 kV CM, 1 kV DM immunity tests-conducted disturbances) III IEC 61000-4-5 || voltage interruptions 100 % during 100 ms immunity tests-conducted disturbances) IEC 60255-11 || 1 MHz damped oscillating wave 2.5 kV CM, 2.5 kV DM immunity tests-conducted disturbances) ANSI C37.90.1 || 100 kHz damped oscillating wave 2.5 kV CM, 1 kV DM immunity tests-conducted disturbances) IEC 61000-4-12 || conducted disturbance emission emission tests) IEC 60255-25 || conducted disturbance emission emission tests) A EN 55022 || disturbing field emission emission tests) IEC 60255-25 || disturbing field emission emission tests) A EN 55022 || electrostatic discharge 8 kV air, 4 kV contact immunity tests-radiated disturbances) ANSI C37.90.3 || electrostatic discharge 8 kV air, 6 kV contact immunity tests-radiated disturbances) IEC 60255-22-2

Documents