Schneider Electric
8501XO40XTE1V02
NEMA Control Relay, Type X, timing, 1 minute on delay, 10A resistive at 600 VAC, 4 normally open, 120 VAC 60 Hz coil
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price
Additional Information
- Part Number
- 8501XO40XTE1V02
- UPC
- 785901537434
- UNSPSC
- 39122331
- Tariff Code
- 8536490080
- Country of Origin
- MX
Environment
- Product Certifications
- CSA LR60905 class 3211 03 || UL listed file E78403 CCN NKCR
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1310013EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1310013
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- [Uc] Control Circuit Voltage
- 110 V AC 50 Hz || 120 V AC 60 Hz
- Ambient Air Temperature For Operation
- -40-160 °F
- Height
- 3.5 in
- Control Circuit Voltage Limits
- operational 0.85...1.1 Uc AC 50/60 Hz
- Mounting Support
- panel
- Contacts Type And Composition
- 4 NO 4 standard contact cartridges
- Rated Breaking Capacity
- 6 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 3 A 240 V AC inductive control circuit UL 508 || 1.5 A 480 V AC inductive control circuit UL 508 || 1.2 A 600 V AC inductive control circuit UL 508 || 10 A <= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301...600 V DC inductive control circuit UL 508 || 4 A 125 V DC resistive control circuit UL 508
- Inrush Power In Va
- 148-148 VA 60 Hz || 143-143 VA 50 Hz
- [Icm] Rated Short-Circuit Making Capacity
- 60 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 30 A 240 V AC inductive control circuit UL 508 || 15 A 480 V AC inductive control circuit UL 508 || 12 A 600 V AC inductive control circuit UL 508 || 10 A <= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301...600 V DC inductive control circuit UL 508 || 4 A 125 V DC inductive control circuit UL 508
- Time Delay Range
- 0.2...60 s
- Hold-In Power Consumption In Va
- 23-23 VA 60 Hz || 25-25 VA 50 Hz
- Electrical Connection
- screw clamp terminals
- Operating Time
- 15 ms - pick-up || 16 ms - drop-out
- Awg Gauge
- AWG 18...AWG 12 copper
- Width
- 2.23 in
- Tightening Torque
- control circuit 1.02-1.36 N.m screw terminal
- Time Delay Type
- on-delay
- Depth
- 6.55 in
Specifications
- Line Rated Current
- 10 A AC || 5 A DC
- Range Of Product
- 8501X
- Product Or Component Type
- relay
- Maximum Switching Voltage
- 600 V AC
- Relay Type
- timing
- Poles Description
- 4P
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther