AP8831

Rack PDU 2G, Metered, ZeroU, 15A, 100-120V, (10) 5-15
AP8831
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

Conformance

Product Certifications
cUL Listed || PSE || UL Listed
Standards
FCC Part 15 class A || ICES-003 || UL 60950-1

Contractual warranty

Warranty
2 years repair or replace

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1712014_EN
Sustainable Offer Status
Green Premium product
Take-Back
Take-back program available
Lead Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Optimized Energy Efficiency
Energy efficient product
Circularity Profile
ENVEOLI1712014_EN
Eu Rohs Directive
Compliant with Exemptions

Physical

Height
90.2 cm
Net Weight
4.08 kg
Mounting Location
side
Mounting Mode
rack-mounted
Color
Black
Mounting Position
vertical
Width
5.5 cm
Depth
4.4 cm

Input

Input Frequency
50/60 Hz
Line Rated Current
12 A

Environmental

Storage Relative Humidity
5-95 %
Ambient Air Temperature For Operation
-5-60 °C
Storage Altitude
0-50000 ft
Ambient Air Temperature For Storage
-25-65 °C
Relative Humidity
5-95 %
Operating Altitude
0...10000 ft

Overview

Lead Time
Usually in Stock
Presentation
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Specifications

Number Of Cables
1
Cable Length
9.84 ft
Main Input Voltage
100 V || 120 V
Number Of Rack Unit
0U
Provided Equipment
Installation guide || Rack Mounting brackets || Serial configuration cable || Safety guide

Documents

Data Sheet

Download