Schneider Electric
ATS22C17Q
soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 440V, 45 to 90kW
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
€1,208.70
1
Payment methods:
A total of 113 Parts In-Stock from 35 Distributors
Product Conditions:
Offer with manufacturer lead time
Ships in:On Request
Best price:
€1,139.07
Additional Information
- Part Number
- ATS22C17Q
- UNSPSC
- 39121521
- Tariff Code
- 8504404000
- Country of Origin
- ID
Environment
- Product Certifications
- CSA || C-tick || GOST || UL || CCC
- Standards
- IEC 60947-4-2
- Electromagnetic Compatibility
- conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 || voltage/current impulse level 3 IEC 61000-4-5
- Ambient Air Temperature For Operation
- -10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
- Shock Resistance
- 15 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm 2-13 Hz)IEC 60068-2-6
- Pollution Degree
- level 2 IEC 60664-1
- Noise Level
- 56 dB
- Ambient Air Temperature For Storage
- -25-70 °C
- Relative Humidity
- 0-95 % without condensation or dripping water IEC 60068-2-3
- Operating Altitude
- <= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Device Connection
- to the motor delta terminals || in the motor supply line
- Network Frequency
- 45...66 Hz
- Minimum Switching Current
- 100 mA 12 V DC relay outputs)
- [Uc] Control Circuit Voltage
- 230 V - 15...10 % 50/60 Hz
- Height
- 356 mm
- Discrete Output Type
- relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
- Maximum Switching Current
- 5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
- Discrete Input Voltage
- 24 V <= 30 V
- Marking
- CE
- Power Range
- 30-50 kW 200-240 V 3 phase || 55-100 kW 380-440 V 3 phase
- Net Weight
- 18 kg
- Output Current
- 0.4...1 Icl adjustable
- Installed Device
- 31
- Connector Type
- 1 RJ45
- Motor Starter Type
- soft starter
- Communication Data Link
- serial
- Function Available
- internal bypass
- Discrete Output Number
- 2
- Control Circuit Consumption
- 20 W
- Communication Port Protocol
- Modbus
- Supply Voltage Limits
- 195-484 V
- Discrete Input Type
- LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
- Physical Interface
- RS485 multidrop
- Type Of Cooling
- forced convection
- Discrete Input Number
- 3
- Assembly Style
- with heat sink
- Operating Position
- vertical +/- 10 degree
- Ptc Probe Input
- 750 Ohm
- Width
- 150 mm
- Transmission Rate
- 4800, 9600 or 19200 bps
- Depth
- 229.5 mm
- Discrete Input Logic
- positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
- Protection Type
- phase failure line || thermal protection motor || thermal protection starter
- Supply Frequency
- 50...60 Hz - 10...10 %
Specifications
- Product Destination
- asynchronous motors
- [Us] Rated Supply Voltage
- 230...440 V - 15...10 %
- Range Of Product
- Altistart 22
- Product Or Component Type
- soft starter
- Component Name
- ATS22
- Phase
- 3 phase
- Power Dissipation In W
- 91 W for standard applications
- Icl Starter Rating
- 170 A connection in the motor supply line for standard applications
- Type Of Start
- start with torque control (current limited to 3.5 In)
- Utilisation Category
- AC-53A
- Product Specific Application
- pumps and fans
- Ip Degree Of Protection
- IP00
- Factory Setting Current
- 162 A
- Motor Power Kw
- 45 kW 230 V || 90 kW 400 V || 90 kW 440 V
Documents
Data Sheet
DownloadCAD Models
traceparts
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther