soft starter for asynchronous motor, Altistart 22, control 230V, 230V, 160kW
ATS22C59S6
ATS22C59S6
ATS22C59S6
ATS22C59S6
ATS22C59S6
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
€3,267.11

Additional Information

Part Number
ATS22C59S6
UNSPSC
39121521
Tariff Code
8504404000
Country of Origin
CN

Environment

Product Certifications
CCC || UL || CSA || GOST || C-tick
Standards
EN/IEC 60947-4-2
Electromagnetic Compatibility
conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 || voltage/current impulse level 3 IEC 61000-4-5
Ambient Air Temperature For Operation
-10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
Shock Resistance
15 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
1 gn 13-200 Hz)EN/IEC 60068-2-6 || 1.5 mm 2-13 Hz)EN/IEC 60068-2-6
Pollution Degree
level 2 IEC 60664-1
Noise Level
56 dB
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
0-95 % without condensation or dripping water EN/IEC 60068-2-3
Operating Altitude
<= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Device Connection
in the motor supply line
Network Frequency
45...66 Hz
Minimum Switching Current
100 mA 12 V DC relay outputs)
[Uc] Control Circuit Voltage
230 V - 15...10 % 50/60 Hz
Height
455 mm
Discrete Output Type
relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Maximum Switching Current
5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
Discrete Input Voltage
24 V <= 30 V
Marking
CE
Power Range
110-220 kW 200-240 V 3 phase || 250-500 kW 480-500 V 3 phase || 250-500 kW 380-440 V 3 phase
Net Weight
50 kg
Output Current
0.4...1 Icl adjustable
Installed Device
31
Connector Type
1 RJ45
Motor Starter Type
soft starter
Communication Data Link
serial
Function Available
internal bypass
Discrete Output Number
2
Control Circuit Consumption
20 W
Communication Port Protocol
Modbus
Supply Voltage Limits
195-660 V
Discrete Input Type
LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
Physical Interface
RS485 multidrop
Type Of Cooling
forced convection
Discrete Input Number
3
Assembly Style
with heat sink
Operating Position
vertical +/- 10 degree
Ptc Probe Input
750 Ohm
Width
304 mm
Transmission Rate
4800, 9600 or 19200 bps
Depth
339.7 mm
Discrete Input Logic
positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
Protection Type
phase failure line || thermal protection motor || thermal protection starter
Supply Frequency
50...60 Hz - 10...10 %

Specifications

Product Destination
asynchronous motors
[Us] Rated Supply Voltage
230...600 V - 15...10 %
Range Of Product
Altistart 22
Product Or Component Type
soft starter
Component Name
ATS22
Phase
3 phase
Power Dissipation In W
251 W for standard applications
Icl Starter Rating
590 A connection in the motor supply line for standard applications
Type Of Start
start with torque control (current limited to 3.5 In)
Utilisation Category
AC-53A
Product Specific Application
pumps and fans
Ip Degree Of Protection
IP00
Factory Setting Current
477 A
Motor Power Kw
160 kW 230 V || 315 kW 400 V || 355 kW 440 V || 400 kW 500 V