Schneider Electric

ATV312HU40M3412

variable speed drive ATV312 - 4kW - 8.4kVA - 180 W - 200..240 V - 3-phase supply
ATV312HU40M3412
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Additional Information

Part Number
ATV312HU40M3412
UNSPSC
39122001
Tariff Code
8504404000
Country of Origin
ID

Specifications

Product Destination
asynchronous motors
Range Of Product
Altivar 312 Solar
Product Or Component Type
variable speed drive
Product Specific Application
pumping station with photovoltaic arrays
Assembly Style
with heat sink
Device Short Name
ATV312

Contractual warranty

Warranty
18 months

Complementary

Prospective Line Isc
1 kA
Network Frequency
47.5...63 Hz
Discrete Input Logic
logic input not wired LI1...LI4), < 13 V || negative logic (source) LI1...LI6), > 19 V || positive logic (source) LI1...LI6), < 5 V, > 11 V
Height
184 mm
Acceleration And Deceleration Ramps
S, U or customized || linear adjustable separately from 0.1 to 999.9 s
Line Current
21.1 A 240 V || 24.2 A 200 V, Isc = 1 kA
Time Constant
5 ms for reference change
Electrical Connection
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5-2.5 mm² AWG 14 || L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5-2.5 mm² AWG 14
Standards
IEC 61800-5-1 || IEC 61800-3
Speed Drive Output Frequency
0.5-500 Hz
Discrete Output Type
configurable relay logic R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles || configurable relay logic R2A, R2B) NC - 100000 cycles
Transmission Frame
RTU
Asynchronous Motor Control Profile
factory set: energy saving mode
Maximum Switching Current
2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms R1-R2) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms R1-R2) || 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms R1-R2) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms R1-R2)
Analogue Output Type
AOC configurable current 0...20 mA 800 Ohm 8 bits || AOV configurable voltage 0...10 V 470 Ohm 8 bits
Transient Overtorque
150-170 % of nominal motor torque
Electromagnetic Compatibility
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Insulation Resistance
>= 500 mOhm 500 V DC for 1 minute
Marking
CE
Dielectric Strength
2040 V DC between earth and power terminals || 2880 V AC between control and power terminals
Response Time
AOV, AOC 8 ms analog || R1A, R1B, R1C, R2A, R2B 8 ms discrete
Motor Power Kw
4 kW
Phase
3 phase
Power Dissipation In W
180 W at nominal load
Net Weight
2.9 kg
Frequency Resolution
analog input 0.1...100 Hz || display unit 0.1 Hz
Connector Type
1 RJ45 Modbus/CANopen
Switching Frequency
2...16 kHz adjustable
Maximum Transient Current
26.3 A 60 s
Number Of Drive
127 CANopen || 31 Modbus
Analogue Input Number
3
Motor Slip Compensation
adjustable || suppressable || automatic whatever the load
Discrete Output Number
2
[Us] Rated Supply Voltage
200...240 V - 5...5 %
Discrete Input Type
LI1...LI6) programmable 24 V, 0-100 mA PLC 3500 Ohm
Communication Port Protocol
CANopen || Modbus
Regulation Loop
frequency PI regulator
Supply Voltage Limits
170-264 V
Minimum Switching Current
R1-R2 10 mA 5 V DC
Analogue Output Number
2
Physical Interface
RS485 multidrop serial link
Transmission Rate
10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen || 4800, 9600 or 19200 bps Modbus
Insulation
electrical between power and control
Speed Range
1-50
Discrete Input Number
6
Local Signalling
for drive voltage 1 LED (red) || for CANopen bus status four 7-segment display units
Linearity Error
+/- 0.2 % output
Number Of Addresses
1-127 CANopen || 1-247 Modbus
Apparent Power
8.4 kVA
Output Voltage
<= power supply voltage
Nominal Switching Frequency
4 kHz
Emc Filter
without EMC filter
Width
142 mm
Analogue Input Type
AI1 configurable voltage 0...10 V 30 V max 30000 Ohm || AI2 configurable voltage +/- 10 V 30 V max 30000 Ohm || AI3 configurable current 0...20 mA 250 Ohm
Braking To Standstill
by DC injection
Depth
152 mm
Tightening Torque
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 0.6-0.6 N.m || L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 0.8-0.8 N.m
Continuous Output Current
17.5 A 4 kHz
Protection Type
input phase breaks drive || line supply overvoltage and undervoltage safety circuits drive || line supply phase loss safety function, for three phases supply drive || motor phase breaks drive || overcurrent between output phases and earth (on power up only) drive || overheating protection drive || short-circuit between motor phases drive || thermal protection motor
Maximum Horse Power Rating
5 hp
Supply
internal supply for logic inputs 19...30 V, <100 A overload and short-circuit protection || internal supply for reference potentiometer (2.2 to 10 kOhm) 10...10.8 V, <10 A overload and short-circuit protection
Braking Torque
<= 150 % 60 s with braking resistor || 100 % with braking resistor continuously || 150 % without braking resistor
Supply Frequency
50...60 Hz - 5...5 %
Option Card
communication card CANopen daisy chain || communication card DeviceNet || communication card Fipio || communication card Modbus TCP || communication card Profibus DP
Sampling Duration
AI1, AI2, AI3 8 ms analog || LI1...LI6 4 ms discrete

Environment

Pollution Degree
2
Ambient Air Temperature For Operation
-10-50 °C without derating with protective cover on top of the drive) || -10-60 °C with derating factor without protective cover on top of the drive)
Shock Resistance
15 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm 3-13 Hz)EN/IEC 60068-2-6
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Ip Degree Of Protection
IP20 without cover plate
Operating Altitude
<= 3280.84 ft (1000 m) without derating || >= 3280.84 ft (1000 m) with current derating 1 % per 100 m
Operating Position
vertical +/- 10 degree
Protective Treatment
TC

Documents

Data Sheet

Download

Related products