BJA36060

Circuit breaker, PowerPacT B, 60A, 3 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, ABC
BJA36060
BJA36060
BJA36060
BJA36060
BJA36060
BJA36060
BJA36060
BJA36060
BJA36060
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1610005EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free product

Complementary

Mounting Mode
I-Line
Network Frequency
50/60 Hz
[Ics] Rated Service Breaking Capacity
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 10 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology
thermal-magnetic
Height
137 mm
Connection Pitch
27 mm
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz UL 489
Tightening Torque
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Breaking Capacity Code
J
9 Mm Pitches
9
Local Signalling
presence of auxiliary contacts flag green)
Number Of Slots
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Electrical Connection
I-Line connection, line || lugs, load
Mounting Height
114 mm
Net Weight
1.315 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Control Type
toggle
Circuit Breaker Application
HACR rated
Wire Stripping Length
20 mm
Line Rated Current
60-60 A
Utilisation Category
category A
Continuous Current Rating
80 %
Breaking Capacity
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
[Ui] Rated Insulation Voltage
800 V IEC 60947-2
Mechanical Durability
20000 cycles IEC 947-1 Annex K ed 5.2
Suitability For Isolation
yes IEC 60947-2
Electrical Durability
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Poles Description
3P
Quantity Per Set
set of 1
Awg Gauge
AWG 14...AWG 2/0 aluminium/copper
Color
Gray RAL 7016)
Width
81 mm
Depth
89 mm
Phase Connection
ABC

Environment

Ik Degree Of Protection
IK07 IEC 62262
Ambient Air Temperature For Operation
-25-70 °C
Standards
UL 489 || GB 14048.2 || CSA C22.2 No 5 || NEMA AB1 || EN/IEC 60947-2 || EN/IEC 60947-5-1 || NMX J-266
Product Certifications
UL || IEC || CCC || EAC || CSA || NOM
Ip Degree Of Protection
front cover IP40 IEC 60529
Pollution Degree
3 IEC 60947-1
Ambient Air Temperature For Storage
-50-85 °C
Quality Labels
CE
Operating Altitude
< 6561.68 ft (2000 m) without derating || 5000 m with derating

Specifications

Product Or Component Type
circuit breaker
Product Name
PowerPact B
Range
PowerPact
Device Application
distribution
Device Short Name
BJ 060

Documents

Data Sheet

Download

Related products