GV2P03KD09BL

Motor Starter Kit, TeSys, LC1D09BL contactor, GV2P03 motor starter protector, 24 VDC coil, 0.25 to 0.40A trip
GV2P03KD09BL
GV2P03KD09BL
GV2P03KD09BL
GV2P03KD09BL
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Additional Information

Part Number
GV2P03KD09BL
UNSPSC
39121521

Specifications

Product Certifications
GL || UL || LROS (Lloyds register of shipping) || CCC || RINA || BV || GOST || DNV || CSA
[Uc] Control Circuit Voltage
24 V DC
[Ue] Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Power Dissipation Per Pole
1.56 W AC-1 || 0.2 W AC-3
Average Impedance
2.5 mOhm - Ith 25 A 50 Hz power circuit
Auxiliary Contact Composition
1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
25 A 60 °C power circuit || 10 A 60 °C signalling circuit
Phase Failure Sensitivity
yes IEC 60947-4-1
Mounting Support
plate || rail
Control Circuit Type
DC low consumption
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
resistive load || motor control
Rated Breaking Capacity
250 A 440 V power circuit IEC 60947
Product Or Component Type
motor starter
Irms Rated Making Capacity
250 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
Associated Fuse Rating
10 A gG signalling circuit IEC 60947-5-1 || 25 A gG <= 690 V type 1 power circuit || 20 A gG <= 690 V type 2 power circuit
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Connections - Terminals
power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || power circuit screw clamp terminals 1 1-4 mm²solid without cable end || power circuit screw clamp terminals 2 1-4 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end
Range
TeSys
Pole Contact Composition
3 NO
Utilisation Category
AC-3 || AC-1 || AC-4
[Ie] Rated Operational Current
9 A 60 °C) <= 440 V AC AC-3 power circuit || 25 A 60 °C) <= 440 V AC AC-1 power circuit
Maximum Operating Rate
3600 cyc/h 60 °C
Suitability For Isolation
yes IEC 60947-1
Tightening Torque
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
Trip Unit Rating
0.25-0.4 A
Electrical Durability
0.6 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 9 A AC-3 <= 440 V
Mechanical Durability
30 Mcycles
Poles Description
3P
Operating Time
65.45...88.55 ms closing || 20...30 ms opening
Overvoltage Category
III
Motor Power Kw
2.2 kW 220...230 V AC 50/60 Hz AC-3) || 4 kW 380...400 V AC 50/60 Hz AC-3) || 4 kW 415...440 V AC 50/60 Hz AC-3) || 5.5 kW 500 V AC 50/60 Hz AC-3) || 5.5 kW 660...690 V AC 50/60 Hz AC-3) || 2.2 kW 400 V AC 50/60 Hz AC-4)
Maximum Horse Power Rating
1 hp 230/240 V at AC 50/60 Hz for 1 phase || 2 hp 200/208 V at AC 50/60 Hz for 3 phase || 2 hp 230/240 V at AC 50/60 Hz for 3 phase || 5 hp 460/480 V at AC 50/60 Hz for 3 phase || 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase || 0.33 hp 115 V at AC 50/60 Hz for 1 phase
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
Trip Unit Technology
thermal-magnetic
[Icw] Rated Short-Time Withstand Current
105 A 40 °C - 10 s power circuit || 210 A 40 °C - 1 s power circuit || 30 A 40 °C - 10 min power circuit || 61 A 40 °C - 1 min power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
Protective Cover
with

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current
5 mA signalling circuit
Line Rated Current
0.4 A
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz IEC 60947-2
Connections - Terminals
screw clamp terminals 2 1-6 mm² solid || screw clamp terminals 2 1.5-6 mm² flexible without cable end || screw clamp terminals 2 1-4 mm² flexible with cable end
Control Circuit Voltage Limits
drop-out 0.1...0.3 Uc DC 60 °C) || operational 0.8...1.25 Uc DC 60 °C)
Rated Duty
continuous IEC 60947-4-1
Contact Compatibility
M5
Magnetic Tripping Current
5-5 A
Contactor Coil Voltage
24 V DC low consumption
[Ith] Conventional Free Air Thermal Current
0.4 A IEC 60947-4-1
Hold-In Power Consumption In W
2.4-2.4 W 20 °C
Motor Power Kw
0.09-0.09 kW 400/415 V AC 50/60 Hz
Insulation Resistance
> 10 MOhm signalling circuit
Maximum Operating Rate
25 cyc/h
Operating Position
any position
Power Range
1.1-2 kW 200-240 V 3 phase || 2.2-3 kW 380-440 V 3 phase || 4-6 kW 380-440 V 3 phase || 4-6 kW 480-500 V 3 phase
Utilisation Category
AC-3 IEC 60947-4-1 || category A IEC 60947-2
Fixing Mode
35 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws)
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-2
[Ics] Rated Service Short-Circuit Breaking Capacity
100 % 690 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2
Control Type
rotary knob
Coil Technology
built-in bidirectional peak limiting diode suppressor
Power Dissipation Per Pole
2.5 W
Electrical Durability
100000 cycles AC-3 440 V
Time Constant
40 ms
Motor Starter Type
direct on-line contactor
Minimum Switching Voltage
17 V signalling circuit
Breaking Capacity
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Mechanical Durability
100000 cycles
Signalling Circuit Frequency
25...400 Hz
[Ui] Rated Insulation Voltage
690 V AC 50/60 Hz IEC 60947-2
Tightening Torque
1.7 N.m screw clamp terminals
Direct Connector
without
Inrush Power In W
2.4-2.4 W 20 °C)
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Network Frequency
50/60 Hz IEC 60947-4-1

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive
Compliant

Environment

Ik Degree Of Protection
IK04
Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Ambient Air Temperature For Operation
-20-60 °C
Ambient Air Temperature For Operation
-5-60 °C
Height
77 mm
Standards
NF C 63-120 || IEC 60947-4-1 || NF C 79-130 || IEC 60947-2 || NF C 63-650 || CSA C22.2 || VDE 0113 || VDE 0660 || EN 60204 || IEC 60947-1 || UL 508
Climatic Withstand
IACS E10
Pollution Degree
3
Product Certifications
EZU || ATEX || EAC || UL || TSE || CCC || RINA || LROS (Lloyds register of shipping) || BV || GL || CSA || UL 508 type E || DNV
Net Weight
0.48 kg
Depth
97 mm
Flame Retardance
V1 conforming to UL 94
Ambient Air Temperature For Storage
-60-80 °C
Ambient Air Temperature For Storage
-40-80 °C
Width
45 mm
Height
89 mm
Protective Treatment
TH
Ip Degree Of Protection
IP20 IEC 60529
Ip Degree Of Protection
IP20 front face IEC 60529
Operating Altitude
6561.68 ft (2000 m)
Operating Altitude
9842.52 ft (3000 m) without derating
Fire Resistance
850 °C IEC 60695-2-1
Depth
95 mm
Permissible Ambient Air Temperature Around The Device
-40-70 °C at Uc