JRA36225

Circuit breaker, PowerPacT J, 225A, 3 pole, 600VAC, 100kA, I-Line, thermal magnetic, 80%, ABC
JRA36225
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2206031EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI2206031EN
Eu Rohs Directive
Compliant with Exemptions

Complementary

Mounting Mode
I-Line bracket)
Network Frequency
50/60 Hz
Terminal Identifier
AL250JD
[Ics] Rated Service Breaking Capacity
150 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 690 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology
thermal-magnetic
Height
191 mm
[Ue] Rated Operational Voltage
600 V AC 50/60 Hz IEC 60947-3
Tightening Torque
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Mounting Support
bracket
Breaking Capacity Code
R
Magnetic Tripping Current
2250-2250 A
Local Signalling
switched off (OFF) 1 trip indicator green)
Number Of Slots
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Electrical Connection
I-Line connection, line || lugs, load
Mounting Height
4.5 in
Net Weight
2.4 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Magnetic Hold Current
1125 A
Control Type
toggle
Circuit Breaker Application
HACR rated
Wire Stripping Length
25 mm
Line Rated Current
225-225 A
Utilisation Category
category A
Long Time Pick-Up Adjustment Range
0.25...1 x In
Continuous Current Rating
80 %
Breaking Capacity
200 kA 240 V AC 50/60 Hz UL 489 || 200 kA 480 V AC 50/60 Hz UL 489 || 100 kA 600 V AC 50/60 Hz UL 489
[Ui] Rated Insulation Voltage
750 V IEC 60947-2
Suitability For Isolation
yes IEC 60947-2
Communication Interface
Modbus
Poles Description
3P
Protection Type
overload protection || short-circuit protection
Awg Gauge
AWG 3/0...350 kcmil aluminium/copper terminals
Width
104 mm
Depth
86 mm
Phase Connection
ABC

Environment

Ambient Air Temperature For Operation
-2-70 °C
Standards
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Certifications
UL || CSA || NOM
Ip Degree Of Protection
front cover IP40
Pollution Degree
3
Ambient Air Temperature For Storage
-50-85 °C
Quality Labels
CE
Operating Altitude
< 6561.68 ft (2000 m) without derating || 5000 m with derating

Specifications

Product Or Component Type
circuit breaker

Documents

Data Sheet

Download